Emerson Fisher 785C Instruction Manual page 17

Piston actuators
Hide thumbs Also See for Fisher 785C:
Table of Contents

Advertisement

Instruction Manual
D104483X012
Figure 13. Handpump Schematic: Fast Stroke MHQ Handpump for 785C Spring Return Rod Retract (Fail Up),
Single- or Double-Acting
PNEUMATIC REMOTE CONTROL TO CLOSE
 PRESSURIZED PERMANENTLY THE PNEUMATIC SUPPLY LINE.
PNEUMATIC REMOTE CONTROL TO OPEN
 DE-PRESSURIZED THE PNEUMATIC SUPPLY LINE.
EMERGENCY MANUAL OPERATION
 IN CASE OF PNEUMATIC SUPPLY FAILURE, CLOSE THE STOP VALVE
 351B, SELECT BY THE VALVE "5-D" THE CLOSING OPERATION AND
 ACTUATE THE HAND PUMP "5-P".
 AT THE END OF THE CLOSING OPERATION CLOSE THE VALVE 351A.
 NOTE: THE VALVE "5-D" MUST BE IN "REMOTE CONTROL" POSITION
  AND THE STOP VALVES 351A AND 351B MUST BE OPEN TO ALLOW
  THE OPERATION WITH PNEUMATIC SUPPLY.
1
SINGLE-ACTING SPRING RETURN PNEUMATIC LINEAR ACTUATOR
3
HYDRAULIC CYLINDER
5
MANUAL OVERRIDE
R — RELIEF VALVE
P — HAND PUMP
D — HAND OPERATED DIRECTIONAL CONTROL VALVE
351
STOP VALVE
395
RELIEF VALVE
785C Actuator
May 2022
PNEUMATIC SUPPLY
17