Climate Control - Audi A8 2019 Service Training

Introduction
Table of Contents

Advertisement

Climate control

At vehicle introduction, the 2019 A8 will uses refrigerant
R1234yf in the climate control refrigerant system. Audi has
been using R1234yf since model year 2017.
Components of the R744 refrigerant circuit
Gas cooler
Properties of the R744:
The essential difference between the new air conditioning
system and previous air conditioning systems is the high
working pressures in the system. These are required in
order to use CO
as a refrigerant.
2
48
High Pressure Side A/C
Pressure/Temperature
Sensor G1053
A new refrigerant is known as R744 will be introduced at a
later date. It is C0
and contains neither fluorine nor chlo-
2
rine and is produced in a series of natural processes without
depleting the earth's ozone layer.
System pressure
Up to 1348.8 psi (93 bar) on the low pressure side.
The maximum system pressure on the high pressure side
is 2030.5 psi (140 bar).
Connection to air conditioner
with evaporator
Service connection,
low pressure side
Service connection,
high pressure side
Expansion valve
Low Pressure Side A/C Pres-
sure/Temperature Sensor
G1052
Accumulator
Coaxial refrigerant line
Pressure relief valve,
low pressure side
AC compressor with pres-
sure relief valve,
high pressure side
662_120