  • Page 1 Assembly Instructions Shelter type: SR8060-F Email : Sales@nobutts.com SR8060F-01-02112021-USA Web : www.nobutts.com Tel : 1-888-662-8887...
  • Page 2 Exploded view 8 8 8 Tools required: Drill/Screwdriver 17mm Wrench Mallet T25 Torx bit...
  • Page 3: Parts List

    PARTS LIST ITEM QTY. PART NAME DRG NUMBER Size (inch) IMAGE 78.74 x 40.74 S1C Frame 4.3 x 4.3 x 1.57 CB1 Bracket 4.33 x 1.57 JF1 Bracket 40.35 ST1 Roof Tie EC40 1.6 X 1.6 40x40 End cap 1.57 x 1.57 x 3.94 FT1 Bracket 1.57 x 3.15 x 4.17 FT3 Bracket...
  • Page 4 FIXINGS Fittings Bolt set M10 BTANCM12100 1.5" M10/12 x 100 mm 1" Tech Black M10 x 60mm Washer Concrete Bolt screw Tech Caps screw Pack A+B Image...
  • Page 5 Step 1 Assemble S1C frames to make up the main structure using CB1 brackets for the corners and JF1 brackets for the straight joints. Please note 1.5" Tec Screws are for roof panels only MEASURE THE WIDTH AND DEPTH OF THE SHELTER TO CHECK CORRECT ALIGNMENT.
  • Page 6 Step 2 Use JF1 and CB1 brackets to attach the S1C frame and ST1 Tie bars.
  • Page 7 Step 3 Attach AR1R rafters using DR brackets. Secure the AR1IS end panels to S1 frames using 1" tec screws. The end rafters need to be placed in position at the same time as the end panels. AR1R AR1R AR1R AR1R AR1IS AR1IS...
  • Page 8 Step 4 Attach the AR1CLTO and AR1CLTI to the top of the rafters The AR1CLTO are to be lined up near the end panels and the AR1CLTI have to be spaced centrally. The ARFSO and ARFSI parts are to be attached to the lower part of the rafters as shown below.
  • Page 9 Step 5 Attach the AR1POA roof panels on the outer edges of the shelter nearest to the end panels and the AR1PIA pannels need to be equaly spaced along the centre. Cap off the top using AR1CUTO and AR1CUTI as shown below. Use the AR1TS strips to cover the gaps between the panels.
  • Page 10 PLAN VIEW OVERALL DIMENSIONS AND GROUND FIXING POSITIONS Suggested size for concrete base: 8inch oversized on all 4 sides. 45.3...
  • Page 11: Maintenance

    Ensure all fittings are tight (for example after a big storm) • Touch up any exposed metal should it get scratched CONTACT DETAILS: No Butts Bin Company, Inc. 16 Birch Lane, Madison, CT 06443 Email : Sales@nobutts.com Web : www.nobutts.com...