After Finishing Work; Service And Maintenance - Festool CT 26 E HEPA Operating Manual

Mobile dust extractors
Hide thumbs Also See for CT 26 E HEPA:
Table of Contents

Advertisement

English
► Replace the top section [2-1] and close the
locking clips [2-2].
Removing the disposal bag [8]
► Open the locking clips [2-2] and remove the
top section of the machine [2-1].
► Close the disposal bag.
► Remove the disposal bag.
► Dispose of the used disposal bag in accord­
ance with statutory regulations.
► Replace the top section [2-1] and close the
locking clips [2-2].
9.3
Changing the filter element
NOTE
Motor damage
► Never operate the extractor without a filter
element fitted as the motor may become
damaged.
► Open the locking clips [2-2] and remove the
top section of the machine [2-1].
► Turn the top section of the machine so that
the main filter is facing upwards (Fig.[9]).
► Fold over the lever [9-3] and remove the re­
tainer. [9-2]
► Remove the used main filter and re­
place [9-1] with a new one.
► Dispose of the used filter in accordance
with statutory regulations.
► Insert the retainer [9-2] and fold over the
lever [9-3] until it engages.
► Replace the top section [2-1] and close the
locking clips [2-2].

10 After finishing work

► Switch off the mobile dust extractor and
pull out the mains plug.
► Wind up the mains power cable.
► Empty the dirt trap.
10
WARNING
Hazardous dust
Damage to the respiratory passage
► Wipe down the mobile dust extractor and
clean all accessories thoroughly using the
extractor (inside and out) before removing
from the working area.
► Parts that you were not able to clean thor­
oughly must be sealed in an airtight plastic
bag prior to transportation.
► Wear a dust mask!
► Place the mobile dust extractor in a dry
room inaccessible to unauthorised users.
10.1 Emptying the dust container
The dust container [2-3] can be emptied once
the top section has been removed.
► After extracting fluids, clean the fill level
sensors [10-1] regularly with a soft cloth
and inspect for damage.

11 Service and maintenance

WARNING
Risk of injury, electric shock
► Always disconnect the mains plug from the
socket before performing maintenance
work on the machine!
► All maintenance and repair work which re­
quires the motor housing to be opened
must only be carried out by an authorised
service workshop.
Customer service and repair only through
manufacturer or service workshops: Please
find the nearest address at: www.festool.com/
service
EKAT
4
5
3
2
1
Use only original Festool spare parts! Order No.
at: www.festool.com/service
A dust test must be performed at least once a
year by the manufacturer or an instructed per­
son. This test may include checks to determine
whether the filter is damaged, the machine is

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ct 36 e hepaCt 48 e hepa

Table of Contents