ABB XAC22175 Operation Manual page 65

Table of Contents

Advertisement

Operation Manual / 4 Product description / A100-L
6 Periodic maintenance / 6.4 Cleaning the compressor during opera-
tion
Principle of wet cleaning
CAUTION
Corrosion and deposits when cleaning
Salt water and cooling water treatment substances damage and adversely
affect turbocharger parts.
Never use salt water, but only pure water for cleaning.
u
To clean the compressor stage during operation, water is injected upstream of the com-
pressor wheel.
The water does not act as a solvent. The coating is removed by the mechanical action of the
impacting droplets. The procedure is perfectly suitable, provided that the contamination
has not progressed too far.
Cleaning several turbochargers
If several turbochargers are installed on an engine, it is recommended to clean one com-
pressor after the other.
CAUTION
Volume of water for cleaning the compressor
Uncontrolled volumes of water can damage the turbocharger and the en-
gine.
Do not guide water pipes to the filler openings.
u
© Copyright 2020 ABB. All rights reserved.
HZTL4034_EN
Rev.P
January 2020

Advertisement

Table of Contents
loading

This manual is also suitable for:

A165-l34

Table of Contents