Fig. 55: Fitting The Gas Inlet Casing (A180-L And Larger) - Threaded Stud Variant; Table 38: Tightening Torque (51087) - ABB XAC22175 Operation Manual

Table of Contents

Advertisement

Operation Manual / 4 Product description / A100-L
8 Disassembly and assembly / 8.17 Fitting the gas inlet casing (≥
A180-L)
8.17.2
Threaded stud variant
Fig. 55: Fitting the gas inlet casing (A180-L and larger) – threaded stud variant
Product
A180-L
A185-L
A190-L
Table 38: Tightening torque (51087)
1) Pre-tightening torque of the screws
1. Coat threaded stud (51086) with high-temperature grease, screw in up to the stop in the
gas outlet casing (61001) and tighten hand-tight.
2. Loop around the gas inlet casing (51001) with the lifting gear and secure it to the crane.
3. Dismantle and remove support (90451) from the gas inlet casing.
4. Push gas inlet casing over the threaded studs up to the gas outlet casing.
5. Coat two nuts (51087) with high-temperature grease and fix gas inlet casing in two op-
posite positions.
6. Coat remaining nuts with high-temperature grease, fit and then tighten crosswise, ini-
tially to the pre-tightening torque and then to the tightening torque.
7. Remove the lifting gear.
8. Connect the flange of the gas inlet casing and the bellows.
9. Fit the insulation segments (51215).
© Copyright 2020 ABB. All rights reserved.
Size
M24
M27
M30
HZTL4034_EN
Tightening torque [Nm]
1)
80
/ 480
1)
100
/ 700
1)
100
/ 920
Rev.P
January 2020