Industio CI-132 Series User’s Manual Industrial 2 Port RS-422/RS-485 Serial Board Feb. 1999 (1st Edition) The content of this manual is also available at Moxa Web Site. Moxa Technologies Co., Ltd. Tel: +866-2-8665-6373 Fax: +886-2-8665-6372 www.moxa.com support@moxa.com.tw...
Page 2
Information provided in this manual is intended to be accurate and reliable. However, Moxa Technologies assumes no responsibility for its use, or for any infringements of rights of the fourth parties which may result from its use.
Page 3
MOXA Internet Services Customer’s satisfaction is always our number one concern. To ensure that customers get the full benefit of our services, Moxa Internet Services have been built for technical support, product inquiry, new driver update, user’s manual update, etc. The followings are the services we provide.
Page 4
If you encounter any problem during the installation, please refer to the “Troubleshooting” chapter. Chapter 1 Introduction Overview and features of the Industio CI-132 Series boards, list of items and overall installation guide. Chapter 2 Hardware Installation Hardware installation for the Industio CI-132 Series boards and connection cable. Hardware configuration utility, Io-irq.exe, is detailed.
Industio - The Industrial Multiport Async Solution The term Industio stands for smart multiport serial I/O solution for industrial applications. The Industio CI-132 Series boards, including CI-132, CI-132I and CI-132IS, are designed for 16-bit ISA/EISA bus. They offer 2 independent RS- 422/RS-485 serial ports for connecting data acquisition equipment and many other serial devices to the PC and its compatible systems.
Page 8
The jumper, JP1, is designed in case of that users forget the CAP address. Normally JP1 is left open. When JP1 is short, the CAP address is forced to a fixed I/O address, 0xA700. While doing quick hardware installation, JP1 is required to be shorted, Industio CI-132 Series User’s Manual...
Broad Applications The board is suitable for many industrial applications. Here are a few: Industrial Automation Factory Automation Remote serial device control Features Industio CI-132 Series User’s Manual...
Page 10
CI-132I 2 RS-422/RS-485 ports, isolation protection, TI550C UART CI-132IS 2 RS-422/RS-485 ports, surge and isolation protection, TI550C UART The following are the outstanding features of Industio CI-132 Series Support 2 independent RS-422 or RS-485 serial ports Standard COM port compatible...
DOS¡Ñ 1 Industio CI-132 Series User’s Manual (This manual) Installation Guide This section gives a brief summary of how to install the Industio CI-132 Series under each supported operating system. The installation is simple and involves the following stages: Configure CI-132 Series with Io-irq.exe...
Hardware Installation The installation of the Industio CI-132 Series consists of hardware and software installation. The hardware installation is detailed in this chapter. The next chapter deals with the software installation for various operating systems. Termination Resistor Port 2 Jumper...
Only one Industio CI-132 Series board is allowed to install in a system. Windows NT and 95/98 are the only operating systems supported. CAP Jumper JP1 is short and I/O address 0xA700 must be free.
Quick Hardware Installation To fully utilize the superior feature of flexible hardware configuration design of the Industio CI-132 Series, a quick and easy method of installation is designed, which absolutely saves you from hardware configuration effort, i.e., installation WITHOUT running configuration program: Io-irq.exe. Simply always short the jumper JP1.
IRQ : INT Vector : 0x1C0 Because the ASIC-designed Industio CI-132 Series has no switch and no jumper for configuring manually the I/O address, IRQ, INT Vector, etc. of the boards, you must run the software utility, Io-irq.exe, in the driver diskette under DOS system to change the hardware configuration.
Io-irq program before inserting the next board. This is to prevent conflict between two boards with same default hardware settings. The Industio CI-132 Series has the following default (factory) settings, I/O address : 0x180 (1st port), 0x188 (2nd port) IRQ : 10...
Page 18
2. Select “Smartio/Industio ISA Family” and press ENTER key. Industio CI-132 Series User’s Manual...
Page 19
Hardware Installation 3. Enter the CAP address of the Industio CI-132 Series board to be configured. 4. Configure the following parameters as necessary. Port Index Indicate the port index for each port. I/O address Enter the base I/O address for each port, either sequentially or not.
Page 20
Note that, currently, port that uses MOXA Windows NT and 95/98 driver will run at the displayed speed. To be clear, when Industio CI-132 Series board is configured as High Speed Spectrum, any port driven by the Moxa-provided Windows NT and 95/98 driver will display the exact working speed. For example, the displayed speed 38.4 Kbps is equal to the working...
Page 21
If not using interrupt vector, type 0 or leave blank as the interrupt vector. There are two modes for the Industio CI-132 Series driver. One is using interrupt vector, the other is not using interrupt vector. Driver employing interrupt vector scheme is supposed to have better performance than employing polling scheme.
Page 22
Industio CI-132 Series User’s Manual 2-10...
Windows NT supports up to 256 serial ports, from COM1 to COM256. To fully integrate the advanced features of Windows NT, multi-process and multi-thread, pure 32-bit Windows NT device drivers are developed for the Industio CI-132 Series multiport boards. The driver conforms to Win32 COMM API standard.
Installing Driver Following is the procedure for installing the Industio CI-132 Series driver for the first time under Windows NT 4.0. Note ! Make sure the board has already been plugged in the system slot if you are doing quick installation.
Page 25
Configuration Panel” dialog box to start the installation. 6. In the “MOXA Configuration Panel” dialog box, click [Add] to enter “Property” dialog box to add the Industio CI-132 Series board. Select the “CI- 132 Series” in the “Board Type” field. If necessary, type the desired interrupt vector address in the “INT Vector”...
Page 26
7. In the “Property” dialog box, select the desired port in the port list and click [Port Setting] to enter the individual “Port #” setting dialog box to change the port COM number mappings or FIFO settings. Industio CI-132 Series User’s Manual...
Page 27
If you need to install more than one board, click [Add] and repeat steps 6 to 8 to configure another board. Up to four Industio CI- 132 Series boards can be installed in a system. Click [OK] to finish the configuration. Industio CI-132 Series User’s Manual...
Page 28
132, with first serial port COM3, has been enabled” for each configured board. If an error message similar to “Cannot find any configured MOXA CI- 132 board!” appears, refer to the “Troubleshooting” chapter for solutions. Industio CI-132 Series User’s Manual...
If you already have installed the driver and want to re-configure the ports, please follow this procedure. 1. In the [Control Panel], click on the [Network] icon and select the [Adapters] tab. 2. Select “MOXA Smartio/Industio Family Adapter” in “Network Adapters”. Industio CI-132 Series User’s Manual...
Page 30
Please see steps 6 to 8 in the previous section, “Installing Driver”, for more details. Click [Remove] to remove the board currently selected from the configured board list. Click [OK] to confirm the configuration changes you made. Click [Cancel] to leave the dialog with the configuration unchanged. Industio CI-132 Series User’s Manual...
Software Installation Updating Driver To update the driver for the Industio CI-132 Series board, simply remove the driver, as described in the next section, and reinstall it as detailed in section, “Installing Driver”. Removing Driver To remove the driver for the Industio CI-132 Series board, 1.
“Removing Driver”. Installing Driver Up to 4 Industio CI-132 Series boards can be installed together as long as the I/O addresses and IRQ number resources are sufficient and available in a system. The following is the procedure for installing Industio CI-132 Series for the first time under Windows 95/98: 1.
Page 33
Software Installation 5. In the “MOXA Configuration Panel” dialog box, click [Add] to enter “Property” dialog box to add the Industio CI-132 Series board. Select the “CI- 132 Series” in the “Board Type” field. If necessary, type the desired interrupt vector address in the “INT Vector”...
Page 34
If “Auto Enumerating COM Number” is not checked, specify the COM number for individual port. For instance, the second port can be out of sequence, say COM10, while the first port is mapped to COM3. Industio CI-132 Series User’s Manual 3-12...
Page 35
If you need to install more than one board, click [Add] and repeat steps 5 to 7 to configure another board. Up to four Industio CI-132 Series boards can be installed in a system. Click [OK] to finish the configuration. 8. Restart Windows 95/98 system. Industio CI-132 Series User’s Manual 3-13...
1. Click on the Taskbar [Start] button, then select [Programs] menu, then [MOXA Utilities] menu and then [MOXA Configuration Panel] icon. 2. The configuration panel will be popped up. Please see steps 4-7 in the previous Section “Installing Driver” for more details. Industio CI-132 Series User’s Manual 3-14...
Manager] tab. Then select and open the “MOXA Smartio/Industio Family” option and then select the “CI-132 Series”. Click on [Properties] button and then select [Device Driver] tab and then click on [Update Driver] button. Industio CI-132 Series User’s Manual 3-15...
Removing Driver Open [Control Panel] icon, and then [Add/Remove Programs] icon, and then select [Install/Uninstall] tab. Then select and open the “MOXA Smartio/Industio Driver” option and then enter [OK] to remove the driver. Industio CI-132 Series User’s Manual 3-16...
“Serial Programming Tools”. Installing Driver Run the installation program, DOSINST.EXE, in the DOS driver diskette. Specify the target API-232 directory (e.g. C:\MOXA) where software driver will be copied. Press F2 to start the installation. Industio CI-132 Series User’s Manual 3-17...
It is strongly recommended to do so. Driver Setup The following are steps for setting up the Industio CI-132 Series driver. Note that it is not intended to illustrate all the convenient functions of the setup programs when configuring the boards. Please refer to the F1 on-line help instructions as running setup program.
Page 41
2. Press Enter to pop up the SETUP dialog box. In the SETUP dialog box, Press F8 to specify the CAP Address and press ENTER and then type Y (YES) to load the configuration of the board to be setup. Industio CI-132 Series User’s Manual 3-19...
Page 42
3. Now the configuration of the desired Industio CI-132 Series board will be shown along with other default settings, such as port number, buffer size, etc. Up to now you have completed the setup for Industio CI-132 Series Note ! board.
Page 43
The receive (input) buffer allocated in the system for each port. F5: Group edit: This is a convenient function that helps you edit the configuration of several ports at one time as a group. Industio CI-132 Series User’s Manual 3-21...
Universal 2/4/8 serial ports Communication Driver Setup driver … Device driver setup O.K. It means the Industio CI-132 Series driver is installed properly. At this point, you are ready to execute application that supports API-232 functions, or start developing applications using API-232 library.
Universal 2/4/8 serial ports Communication Driver Setup driver … None serial port found !! It means the Industio CI-132 Series driver is not installed properly. Please refer to chapter, “Troubleshooting”, for possible reasons and solutions. Unloading Driver To unload (release) the Industio CI-132 Series driver from memory, type "SER-DRV/Q"...
Page 46
Industio CI-132 Series User’s Manual 3-24...
MOXA boards only. MOXA Windows NT or Windows 95/98 device drivers, as well as MOXA boards are required. The drivers are installed separately and detailed in the “Software Installation” chapter. Industio CI-132 Series User’s Manual...
A convenient diagnostic program that provides internal and external testing, such as IRQ, TxD/RxD, UART, CTS/RTS, DTR/DSR, DTR/DCD testing, etc., for the MOXA boards and ports to verify correct operations of both the software and hardware. Industio CI-132 Series User’s Manual...
Page 49
You can also click on one of the specific displayed port in order to visualize the current communication parameters and status of that port. Industio CI-132 Series User’s Manual...
Page 50
Terminal Emulator The Terminal Emulator features multi-windows and supports terminal types of VT100 and ANSI. You can transfer data interactively, send pattern periodically or transfer file using ASCII, XMODEM, YMODEM, ZMODEM and KERMIT protocols. Industio CI-132 Series User’s Manual...
There are two utilities available for DOS: Data Scope and Diagnose, which are detailed below. Data Scope The Data Scope, BIN\SCOPE.EXE, is a suite of utility programs that can help users with system troubleshooting and serial communication debugging. Industio CI-132 Series User’s Manual...
Page 52
ZMODEM and KERMIT protocols. 3. The Diagnostic test utility provides port connection test with two MOXA ports connected via a properly wired cable. Please see on-line help as running BIN\SCOPE.EXE for more usage and capability information. Industio CI-132 Series User’s Manual...
Page 53
Serial Programming Tools Diagnose The Diagnose, BIN\DIAGNOSE.EXE, is a utility that can help users to diagnose the hardware condition of each port of the selected board. See on-line help for more details. Industio CI-132 Series User’s Manual...
RS-485 applications. How to transmit and receive data for Windows NT, 95/98 & DOS We recommend you to configure Industio CI-132 Series ports as follows in order to acquire precise timing control in RS-485 2-wire transmission. Industio CI-132 Series User’s Manual...
Page 55
4. Turn off RTS and ready for receiving data. */ For more information on these functions, please refer to PComm library on-line Help file for Windows NT and Windows 95/98 or API-232.txt file for DOS, respectively. Industio CI-132 Series User’s Manual...
Page 56
Industio CI-132 Series User’s Manual 4-10...
The RS-422 standard uses a balanced voltage digital interface to allow communications of 10M bps on cable length of 4000 feet. Ten receivers can be connected to any one driver for broadcasting systems. RS-422 pin outs for Industio CI-132 Series: CI-132 TxD-(A)
CTS-(A) CTS+(B) RTS+(B) CTS-(A) RTS-(A) Note: Stands for termination resistor near the receiving side Termination Resistor Port 2 Jumper CAP Jumper Interface Switch Termination Resistor Port 1 Jumper Data Mode Switch Industio CI-132 Series Board Industio CI-132 Series User’s Manual...
Troubleshooting Common Industio CI-132 Series problems and possible solutions are listed below. If you still have problems, contact your dealer or Moxa for help. Or use the “Problem Report Form” at the end of this manual to report problems to your dealer at once for faster technical support.
Page 62
Software Causes and Solutions: a. For RS-422 mode, Industio CI-132 Series checks the line status (CTS) before it sends data out if the RTS/CTS flow control feature is set to “Enable” in the configuration or application program. Please refer to the “Connection Cable and Cable Wiring”...
Page 63
Enter the “Configuration Access Port” in HEX: A700 Step 6. The previous hardware configuration will be shown. Modify them if necessary. Remember the CAP address this time. Step 7. Exit the IO-IRQ. Step 8. Power off the PC. Industio CI-132 Series User’s Manual...
Some partial decoded network board may interfere with our board. Please avoid from using 0x300 as I/O address for those network boards. b. Check hardware configuration of Industio CI-132 Series board by IO- IRQ.EXE. Then make sure the hardware configuration, including I/O addresses for each port, Interrupt Vector, IRQ, is identical to that of the driver.
This section is specific for troubleshooting under Windows 95/98. For general problems and solutions, please see the previous section, “General Troubleshooting”. 1. The system fails to find the Industio CI-132 Series board! After system reboot, error message "CI-132 Series (CAP=0x0180, port 1=COM3): Board is not found"...
Make sure you’re using the right driver. b. Check if the board is properly plugged into ISA/EISA bus slot. c. Check if the I/O address and IRQ settings in SETUP program are same as the settings on board. Industio CI-132 Series User’s Manual...
CPU and to prevent any loss of valuable data. PC I/O Port Address Map The following is the list of the I/O port addresses commonly used, which is good for preventing I/O address conflict when configuring Industio CI-132 Series. IO/ Address Device...
Use the following SCO UNIX/OpenServer/XENIX command to start the software installation of a new serial board: # mkdev serial The screen will show: You would like to install a: 1. 1 port card 2. 2 port card 3. 4 port card 4..Industio CI-132 Series User’s Manual...
Page 70
Once the installation is successfully completed, the following serial devices along with their modem devices (upper-case) will be added to the system. tty1a tty1b (first CI-132) tty2a tty2b (second CI-132) Be sure to activate the device by using SCO command: # enable ttyxx Industio CI-132 Series User’s Manual...
Page 71
Problem Report Form Industio CI-132 Series Customer name: Company: Tel: Fax: Email: Date: 1. Moxa Product: CI-132 Series Model : oCI-132 oCI-132I oCI-132IS Serial Number: ____________ 2. Moxa Driver Version: ________________ 3. Moxa hardware settings: 3.1 Please check the hardware configuration by IO-IRQ.EXE from DOS or Windows 95/98 DOS Prompt.
Page 72
Return Procedure For product repair, exchange or refund, you must: Provide evidence of original purchase. Fill out the Problem Report Form (PRF) as detailed as possible for shorter product repair time. Obtain a Return Merchandise Authorization (RMA) number from the sales representative or dealer. Carefully pack the product in an anti-static package, and send it, pre-paid, to the dealer.