CS-A18CKH CU-A18CKH / CS-A24CKH CU-A24CKH
Indoor Unit
AUTO
OFF / ON
Automatic Operation Button
• Press for < 5s to operate Automatic
operation mode.
(Used when the remote control cannot be
used.)
• Press continuously for 5s or < 10s to
operate Test Run/Pump down. "Beep"
sound will be heard at the 5th second.
(Used when test running or servicing.)
• Press continuously for 10s and above to
omit or resume the remote control signal
receiving sound. "Beep, beep" sound will
be heard at the 10th second.
Operation Indication Lamps (LED)
(Green) .......... Lights up in operation,
POWER
(Orange) ......... Lights up in Quiet Mode
QUIET
(Orange) ......... Lights up in Timer Setting.
TIMER
POWERFUL
(Green) ............ Lights up in Ionizer
Operation Mode
• Heating, Cooling, Soft Dry and Automatic
Mode.
Powerful Operation
• Reaches the desired room temperature quickly.
Quiet Operation
• To provide quiet operation.
Random Auto Restart Control
• Operation is restarted randomly after
power failure at previous setting mode.
Anti-Freezing Control
• Anti-Freezing control for indoor heat
exchanger. (Cooling and Soft Dry)
blinks in Automatic
Operation Mode judging
and Hot Start operation.
Operation.
(Orange) ... Lights up in Powerful
Mode Operation.
Mode Operation.
Ionizer Control
• Ionizer control for generate negative ion
in discharge air.
Indoor Fan Speed Control
• High, Medium and Low.
• Automatic Fan Speed Mode
Heating : Fan speed varies from Me
Cooling : Fan rotates at Hi, Me and
Soft Dry : Fan rotates at Lo- speed.
Airflow Direction Control
• Automatic air swing and manual adjusted
by remote control for vertical and horizontal
airflow.
Time Delay Safety Control
• Restarting is inhibited for appro. 3 minutes.
7 Minutes Time Save Control
• Cooling Operation only.
Anti-Dew Formation Control
• Anti-Dew Formation Control for indoor unit
discharge area.
Hot-Start Control
• At Heating Operation the indoor fan will
operate at SLo speed when indoor heat
exchanger temperature reaches 30°C.
Anti Cold Draft Control
• The indoor fan operates at Lo
after that SSLo when the indoor heat
exchanger temperature is low.
(During Heating mode thermal off)
4
→ SSLo in accordance with
indoor heat exchanger.
Lo- speed. Deodorizing
control is available.
Deodorizing control is
available.
(30 sec.)

Advertisement