Compressor; Ipm Module Board - Carrier 40MBAB Series Service Manual

Air handler unit ductless system
Hide thumbs Also See for 40MBAB Series:
Table of Contents

Advertisement

40MBAB: Service Manual
DIAGNOSIS AND SOLUTION (CONT.)
PC 00 - IPM malfunction or IGBT over-strong current protection Diagnosis and Solution
Description: When the voltage signal that the IPM sends to the compressor drive chip is abnormal, the LED displays "PC 00"
and the AC turns off.
Recommended parts to prepare:
• Connection wires

• IPM module board

• Outdoor fan assembly

• Compressor

• Outdoor PCB
Troubleshooting and Repair:
Check the wiring between
PCB and compressor.
Does an error exist?
Is it in working order?
Check the outdoor fan and the
outdoor unit ventilation.
Is it in working order?
Check the compressor
acceptable parameters?
Replace the outdoor PCB.
NOTE: For certain models, the outdoor PCB cannot be removed separately. In this case, the outdoor electric control box should
be replaced as a whole.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
NO
Check the IPM.
YES
YES
resistance values.
Are they within
YES
Ensure proper connections or
YES
replace the wires and connectors.
Replace the IPM board or
NO
replace the outdoor PCB.
Refer to the "Fan Speed is Out of Control"
NO
malfunction solution.
NO
Replace the compressor.
25

Advertisement

Table of Contents
loading

Table of Contents