Installation - NetterVibration VibroScanner VSI Operating Instructions Manual

Table of Contents

Advertisement

Installation

6
Installation
Observe the safety instructions in Ch. Safety, from page 5 on.
Mount the controller on a standard mounting rail in a suitable control cabi-
Mount the
net (Degree of protection IP 65).
controller
Connect the
Controller of the VSI requires an operating voltage of 24V DC.
controller
Depending on the configuration of the DIP switches, the connection is
made via the current outputs or voltage outputs.
Pin assignment of the current output
Pin assignment of the voltage output
The sensors are attached directly to the vibrating application part via the
Mount the
fastening thread (M6, max. screw-in depth 10 mm) or with a plastic clamp
sensor
bracket or a rubberized pipe clamp. Make sure that in case of linear vibra-
tions the longitudinal axis of the sensor is to be aligned parallel to the di-
rection of vibration.
Connect the
Connect the sensor cable with the sensor. The plug is protected against
sensor
polarity reversal. Tighten the union screw hand-tight. Do not use a tool.
Insert the plug of the sensor cable into the 4-pin connection terminal on
the controller.
14
PIN 1: GND
PIN 2: Frequency
PIN 3: GND
PIN 4: Acceleration
PIN 5: GND
PIN 6: Stroke
PIN 7: 0 V
PIN 8: +24V
PIN 1: GND
PIN 2: Frequency
PIN 3: GND
PIN 4: Acceleration
PIN 5: GND
PIN 6: Stroke
PIN 7: 0 V
PIN 8: +24V
Ground frequency
Frequency
Ground acceleration
Acceleration
Ground stroke (vibration ampli-
tude)
Stroke (vibration amplitude)
Ground power supply
Power supply
Ground frequency
frequency
Ground acceleration
Acceleration
Ground stroke (vibration ampli-
tude)
Stroke (vibration amplitude)
Ground power supply
Power supply