Flow Controller Systems FCS KA Operation Manual

Compact peristaltic pump

Advertisement

Quick Links

FCS KA (SS)
Compact Peristaltic Pump
Operation Manual

Advertisement

Table of Contents
loading

Summary of Contents for Flow Controller Systems FCS KA

  • Page 1 FCS KA (SS) Compact Peristaltic Pump Operation Manual...
  • Page 2 Note: Please read the manual carefully before operating the product.  Warning: Connect the power cord to the wall socket directly, and avoid using a power  extension cord. If the power cord or plug has wear or other damage, please disconnect the plug. ...
  • Page 3: Table Of Contents

    Catalogue 1. Product Introduction ................... - 1 - 2. Product Appearance .................... - 1 - 3. Operation Panel ....................- 2 - 4. External Control Instruction ................- 3 - 5. Communication Function Instruction ..............- 7 - 6. Technical Specification ..................- 8 - 7.
  • Page 4: Product Introduction

    FCS KA (SS) 1. Product Introduction FCS KA (SS), with low noise and stable operation, is driven by an integrated stepper motor with a compact structure. The product adopts OLED blue screen display and has an external control interface, which can realize remote control. It can communicate with a computer through standard Modbus communication protocol (RTU mode).
  • Page 5: Operation Panel

    FCS KA (SS) 3. Operation Panel Start/stop Digital Knob Direction Ext. control 100.0 转速 Speed Communication V 01 5V 01 通信地址 address Analog speed 模拟调速 control Operation 运行状态 status Start/Stop Button  Pumps start/stop can be controlled by this button. Press this button once, the pump working status change once.
  • Page 6: External Control Instruction

    4. External Control Instruction FCS KA (SS) series has a 15-pin interface for the external control interface, as the below figure shows. That includes the function of external control start/stop, direction, analog speed regulation, communication, and status output.
  • Page 7 FCS KA (SS) Pin5, RS485A+ Pin6, analog speed regulation 0-5V signal terminal Pin7, analog speed regulation 0-10V signal terminal Pin8, analog speed regulation 4-20mA signal terminal Pin9, analog speed regulation common terminal AGND Pin10, active external control isolated signal common terminal, factory defaults...
  • Page 8 FCS KA (SS) Pin2 connects positive pole of active external control signal, short circuit and then disconnect, the motor will change direction. Do it again, the motor will change direction again. Level mode: Pin10 connects with negative pole of active external control signal.
  • Page 9 FCS KA (SS) signal is displayed “mA” in the screen. Current 4-20mA speed regulation, Pin8 connects to the positive pole of current analog 4-20mA signal. Pin9 connects to the negative pole. Change the current value of the analog signal and the speed changes linearly. 4mA corresponds to speed 0rpm, 20mA corresponds to maximum speed.
  • Page 10: Communication Function Instruction

    FCS KA (SS) 5. Communication Function Instruction The pump supports standard modbus protocol (RTUmode), communication modes are RS485 and USB. It can control the pump start/stop, direction and motor speed, and can read the current running status. USB communication mode: A USB cable is needed (one side is USB-A and the other side is USB-B).
  • Page 11: Technical Specification

    FCS KA (SS) RS485 conversion module 6. Technical Specification 0.0033~365.69 Flow rate Power supply AC100V~240V(50HZ/60HZ) mL/min Start/stop: Switch signal Speed range 0.1~300rpm External control Speed control: 0-5V, 0-10V, 4- 20mA for option Speed 0.1rpm Communication RS485 resolution Digital knob/ Control...
  • Page 12: Main Function And Feature

    FCS KA (SS) 7. Main Function and Feature Suitable Pump Head: FCS KA (SS) easy load pump head.  Digital knob control speed, control speed manually or by external control  interface automatically. Multiple pumps can be controlled by one controller at the same time, RS485 ...
  • Page 13: Maintenance

    FCS KA (SS) 9. Maintenance 9.1 Check the running status of the machine before starting it, ensure that the power supply of the device is reliably grounded. Normal operation can be put into use. The external wiring of the equipment must be operated in the power-off state to prevent burning the equipment.
  • Page 14 FCS KA (SS) 9.6 The data used for testing in this manual is all short duration and may change for longer duration use. 9.7 The current will raise over the rated running current when DC/AC motor starts or blocks, it may be about 3-5 times the rated operating current.
  • Page 15: Warranty & After-Sales Service

    FCS KA (SS) 10. Warranty & After-Sales Service We support 3 years warranty for the pumps, subject to the exceptions below. Our company shall not be liable for any loss, damage, or expense directly or indirectly related to or arising out of the use of its products. This warranty does not obligate our company to bear any costs of removal, installation, transportation, or other charges which may arise in connection with a warranty claim.

This manual is also suitable for:

Fcs ka ss

Table of Contents