Flow Controller Systems FCS KA SS Operation Manual

Compact peristaltic pump
Hide thumbs Also See for FCS KA SS:

Advertisement

Quick Links

FCS KA (SS)
Compact Peristaltic Pump
Operation Manual

Advertisement

loading

Summary of Contents for Flow Controller Systems FCS KA SS

  • Page 1 FCS KA (SS) Compact Peristaltic Pump Operation Manual...
  • Page 2 Note: Ø Please read the manual carefully before operating the product. Warning: Ø The tube may have crack due to wear. It results in the overflow of fluid from tubing. In that time human body and instruments may be harmed. So users must check frequently and change tubing in time. Ø...
  • Page 3 Catalogue 1. Product Introduction ....................................- 4 - 2. Product Appearance ....................................- 4 - 3. Operation Panel ......................................- 4 - 4. External Control Instruction ..................................- 5 - 5. Technical Specification ....................................- 7 - 6. Main Function and Feature ..................................- 8 - 7.
  • Page 4 KA (SS) 1. Product Introduction FCS KA (SS) compact peristaltic pump is driven by stepper motor, with small volume and low noise. Compact structure, it can be stacked. It adopts OLED screen display, with external control interface, which can realize remote control. It can communicate with computer through standard Modbus communication protocol (RTU mode).
  • Page 5 KA (SS) In the stop state, press the digital knob, the lower right corner of the OLED flashes and the value is RS485 communication address (1~32). At this time, you can turn the digital knob to change the value. After setting, press the digital knob to save the data and the screen no longer flashes.
  • Page 6 KA (SS) A+ : Connect to RS485 A+ GD1 : RS485 signal ground ④ . External Control Start/stop Signal Input Port GD2: External control signal common port VDD2: Isolated voltage signal input port IN1: External control start/stop signal input (pulse signal), after adding external control isolation power supply between VDD2 and GD2, IN1 and GD2 are short-circuited and then disconnected, the motor starts to run, and after short-circuiting again, the motor stops.
  • Page 7 POWER_VDD POWER_VDD KA (SS) POWER_COM POWER_COM VDD2 VDD2 5V Power 5V Power 5V电源 5V电源 Supply Supply 电压模 The positive 电流模 The positive 4-20mA 4-20mA pole(+) of 拟量信 pole(+) of 拟量信 current voltage 号正极 号正极 0-5V analog analog signal 0-5V (+) (+)...
  • Page 8 KA (SS) 6. Main Function and Feature Ø Suitable Pump Head: FCS KA (SS). Ø Digital knob control speed, control speed manually or by external control interface automatically. Ø One master can control multiple pumps, RS485 address cannot be repetitive. Ø...
  • Page 9 Electrical surge as a cause of failure is excluded. Ø Chemical attack is excluded. Ø Improper operation or man-made damage as a cause of failure is excluded. Flow Controller Systems 2950 Buskirk Ave Suite 300 Walnut Creek CA 94597 Tel: 925-516-4459 Website: flowcontrollersystems.com Email: justin@fcs-us.net...