10-Second
Digital Thermometer
with Flexible Tip
Your thermometer features a comfortable, soft, flexible tip, which conforms to the
mouth during temperature readings. It is enhanced with beeper, memory and fever
alarm. The following instructions will cover your thermometer's features in further detail.
Thank you for purchasing a MABIS Digital Thermometer. Please read the following
instructions to achieve the most accurate temperatures and safe operation. With
proper care and use, your thermometer will provide you with years of reliable
readings.
What is a "Normal" Temperature?
Although the generally accepted "normal" temperature reading is 98.6 ° F, temperature
readings can vary from 97 ° F to 99 ° F and still may be considered "normal". Variations
in temperature can be attributed to activities such as exercise, smoking, eating and
drinking. Even time of day may influence your temperature. For example, your
temperature is lower in the morning than in the afternoon. Other variations may be
due to the location of the temperature reading. While the oral temperature follows the
guidelines previously described, a rectal temperature is generally 1.0 ° F higher.
Conversely, an axillary (under the arm) temperature will be 1.0 ° F lower.
Features of your MABIS Digital Thermometer
DIGITAL DISPLAY WINDOW
PROBE TIP
Cleaning Instructions
Before and after each use, clean the thermometer with a soft cloth and 70% isopropyl
alcohol diluted with water, or wash with COLD soapy water. An intact unit can be
submersed in water or alcohol. However, do not soak for an extended period of time.
1. The unit must never be sterilized by boiling, gas or steam autoclaves.
2. The use of any other solution or cleaning method beyond the above mentioned
may result in reliability problems with the thermometer and void your warranty.
How to Take Your Temperature
1. Clean and disinfect the thermometer according the instructions provided.
2. Apply a disposable probe cover to the clean, dry thermometer.
3. Determine whether the measurement site will be oral, rectal or underarm.
NOTE: Measurement time may vary based on the selected site.
4. Press the ON/OFF button (the unit will beep) to activate the thermometer.
This is the LCD display test, which insures all parts of the
display are functioning properly.
By continuing to hold the button down, the last measured
temperature will be displayed until the button is released.
Once the button is released or if no reading is stored, an Lo with
a flashing °F will appear in the display followed by a brief flash
of 97.7°F followed by a Lo with a flashing °F to indicate that the
thermometer is ready for measurement.
NOTE: If the room temperature is above 89.6°F, the room temperature will display
instead of the Lo.
Taking an Oral Temperature
Approximate measurement time: 10-20 seconds
1. Using the diagram on the right, place the
probe tip under the tongue as near as
HEAT
possible to the heat pocket. The diagram
POCKET
also shows the temperature variables by
not placing the tip in the heat pocket
area.
NOTE: Drinking hot or cold fluids,
exercising, smoking or performing other
activities may raise or lower your
temperature. Therefore, it is important to
relax for approximately 5 minutes with your
mouth closed prior to taking a reading.
2. The current temperature is shown and the ° F will continue to flash during the
reading.
3. When the peak temperature has been reached, the ° F will stop flashing and the
thermometer will sound four long beeps if the temperature is below 99.5°F. If the
temperature is above 99.5°F the unit will sound twelve short beeps.
4. To turn the unit off, press the ON/OFF button. The unit will automatically shut off
after approximately ten minutes.
NOTE: The mouth must remain closed during the measurement for the most
accurate reading. Opening the mouth could result in an extended measurement time
and may affect the reading.
Taking an Axillary Temperature (under the arm)
Approximate measurement time: 20-30 seconds
1. Wipe the underarm with a dry towel.
2. Place the probe tip under the arm so the tip is touching the skin with the
thermometer perpendicular to the body.
3. Position the arm across the chest so the probe tip is well covered by the arm. This
also insures the probe is not affected by the room's air.
4. When the peak temperature has been reached, the ° F will stop flashing and the
thermometer will sound four long beeps if the temperature is below 99.5°F. If the
temperature is above 99.5°F the unit will sound twelve short beeps.
5. To turn the unit off, press the ON/OFF button. The unit will automatically shut off
after approximately ten minutes.
NOTE: Axillary temperatures are generally 1.0 ° F lower than oral readings.
Taking a Rectal Temperature
Approximate measurement time: 10 seconds
NOTE: Rectal temperatures are an appropriate and reliable method for infants and
small children. Otherwise, this method should only be used when it is impossible or
impractical to take an oral or axillary temperature.
1. After applying the disposable probe cover, apply a water-soluble lubricant to
the tip.
2. Gently insert the probe a MAXIMUM of 1/2" into the rectum.
3. When the peak temperature has been reached, the ° F will stop flashing and the
thermometer will sound four long beeps if the temperature is below 99.5°F. If the
temperature is above 99.5°F the unit will sound twelve short beeps.
BATTERY COVER
4. To turn the unit off, press the ON/OFF button. The unit will automatically power
down after approximately ten minutes.
NOTE: Rectal temperatures are generally 1.0 ° F higher than oral readings.
Using Disposable Probe Covers
It is recommended to use the enclosed disposable probe covers to prevent cross
contamination. Additional probe covers can be purchased from your MABIS Dealer
or with the order form provided.
ON/OFF BUTTON
General Care
1. The thermometer should only be used under the supervision of an adult.
2. Do not walk, run or talk during temperature taking.
3. Clean the thermometer before and after each use.
4. Store the unit in the protective case when not in use.
5. Do not bite the probe.
6. Do not store the unit where it will be exposed to direct sunlight, dust or humidity.
Avoid extreme temperatures.
7. Dropping or subjecting your thermometer to strong shocks should be avoided.
8. Do not attempt to disassemble the unit, except to replace the battery.
9. If ERR displays and measurement is not attainable, the unit must be replaced.
NOTE: Performance of the device may be degraded if: operated outside of stated
temperature and humidity range; stored outside of stated temperature and humidity
range; thermometer undergoes mechanical shock (drop); patient temperature is
below ambient temperature.
Changing the Battery
The battery in your digital thermometer needs to be
replaced when the " " symbol appears in the center of the
display. Replace the battery with a 1.55V LR41 alkaline or
SR41 silver oxide type or equivalent.
To replace the battery,
1. Slide the battery cap away from the unit.
2. Using a non-metal pointed tool, carefully remove the battery and insert the new
battery with the positive (+) side facing up.
3. Carefully slide the battery cap back into place, making sure that the cap fits
snugly to protect the battery compartment from moisture.
NOTE: Please properly dispose the battery away from small children and heat.
Specifications
DISPLAY:
DISPLAY RESOLUTION:
MEASUREMENT RANGE:
HEAT
ACCURACY:
98.8
o
F
POCKET
98.8
o
F
37.1
o
C
37.1
o
C
AVERAGE MEASUREMENT TIME:
98.4
o
F
98.4
o
F
36.9
o
C
36.9
o
C
TONE:
98.1
o
F
36.7
o
C
97.9
o
F
97.9
o
F
36.6
o
C
36.6
o
C
MEMORY:
97.7
o
F
BATTERY:
36.4
o
C
BATTERY LIFE:
AUTOMATIC SHUT-OFF:
AMBIENT OPERATING TEMPERATURE:
STORAGE TEMPERATURE:
DIMENSIONS:
WEIGHT:
Specifications are subject to change without notice. Meets ASTM Standard E1112.
Liquid Crystal Display
0.1°F (0.1°C)
89.6°F (32.0°C) – 111.2°F (44.0°C)
±0.2°F, 98.0°F – 102.0°F (±0.1°C, 37.0°C – 39.0°C)
±0.3°F, 96.4°F – 98.0°F (±0.2°C, 35.8°C – 37.0°C)
±0.3°F, 102.0°F – 106.0°F (±0.2°C, 39.0°C – 41.0°C)
Oral 10-20 seconds. Rectal 10 seconds. Axillary 20-30 seconds
Thermometer beeps when activated and deactivated. After the
measurement is complete, four long beeps sound for
temperatures under 99.5°F (37.5°C). Twelve short beeps sound
for temperatures above 99.5°F (37.5°C).
Displays last measured temperature
One, 1.55V button size battery LR41, SR41 or equivalent
Approximately 2 years
After approximately 10 minutes
°
°
50.0
F to 104.0
F (10.0°C – 40.0°C)
14.0°F – 140.0°F (-10.0°C – 60.0°C)
5-1/2" x 7/8" x 3/8"
0.4 ounces (11.34 grams)
#MABMT 519-BQF 07/05
©2005 MABIS Healthcare
LIMITED LIFETIME WARRANTY
MABIS Healthcare ('MABIS') guarantees that its MABIS Digital Thermometer will be free
from manufacturing defects under normal use for as long as the original
purchaser owns the product.
This warranty covers only normal use, and does not apply to use in any clinical or
commercial applications. This warranty does not cover batteries or other power sources
that may be provided with or used with the MABIS Digital Thermometer. This warranty is
voided if the MABIS Digital Thermometer product is misused or abused in any manner.
If the MABIS Digital Thermometer fails to operate during the time the original
purchaser owns it, return it postage prepaid to: MABIS Healthcare, Attn: Repair
Department, 1931 Norman Drive, Waukegan, IL 60085. MABIS will repair or replace the
defective unit at the option of MABIS Healthcare. Repair or replacement of the defective
unit, at MABIS' option, is the sole remedy under this warranty.
ANY IMPLIED WARRANTIES WHICH THE PURCHASER MAY HAVE ARE LIMITED IN
DURATION TO THE TIME THAT THE ORIGINAL CONSUMER PURCHASER OWNS
THE PRODUCT. Some states do not allow limitations or how long an implied warranty
lasts, so the above limitation may not apply to you.
This warranty constitutes MABIS' only responsibility and obligation to repair and/or
replace materials or components, or refund the purchase price. MABIS will not be
responsible for any indirect, incidental, special, consequential, or punitive damages or
other loss, including, but not limited to, damage to or loss of other property or equipment
and personal injuries, whether to purchaser or others. MABIS shall in no event be liable
to the purchaser for any amount in excess of the cost of repair and/or replacement of the
unit, or the purchase price of the unit. Some states do not allow the exclusive or
limitation of incidental or consequential damages, so the above limitation or exclusion
may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which
vary from state to state.
CUT OUT AND MAIL TO:
MABIS HEALTHCARE
1931 NORMAN DRIVE
WAUKEGAN, IL 60085
THERMOMETER WARRANTY REGISTRATION
(MUST BE COMPLETED WITHIN 10 DAYS OF PURCHASE)
NAME:
ADDRESS:
CITY:
STATE:
PURCHASED FROM:
CITY:
STATE:
DATE PURCHASED:
MODEL PURCHASED:
15-753-000
USER INFORMATION (OPTIONAL)
K MALE
K FEMALE
AGE OF YOUNGEST FAMILY MEMBER
K UNDER 6 MONTHS
K 6 MONTHS - 1 YEAR
K 1 - 3 YEARS
K 3 - 5 YEARS
PROBE COVER ORDER FORM
CUT OUT AND MAIL TO:
MABIS HEALTHCARE
1931 NORMAN DRIVE
WAUKEGAN, IL 60085
Please send
packages of disposable probe covers
#15-618-000 (100 probes per package). Enclosed is $5.00 per
package plus $3.00 for shipping and handling for each order.
PAYMENT METHOD (do not send cash):
Check
Please ship to:
NAME:
ADDRESS:
CITY:
STATE:
PHONE: (
)
NOTE: This order form is for shipments within the United States and Canada.
ZIP:
ZIP:
AGE:
K OLDER
Money Order
ZIP:

Advertisement

loading

Summary of Contents for MABIS 15-753-000

  • Page 1 The following instructions will cover your thermometer’s features in further detail. that may be provided with or used with the MABIS Digital Thermometer. This warranty is thermometer will sound four long beeps if the temperature is below 99.5°F. If the voided if the MABIS Digital Thermometer product is misused or abused in any manner.