Download Print this page

MABIS 15-878-000 Quick Start Manual

8-second ultra ouick read digital thermometer with flexible tip

Advertisement

Quick Links

8-Second Ultra Quick Read
Digital Thermometer
with Flexible Tip
Thank you for purchasing a MABIS Digital Thermometer. Please read the following
instructions to achieve the most accurate temperatures and safe operation. With
proper care and use, your thermometer will provide you with years of reliable read-
ings.
Your thermometer features a comfortable, soft, flexible tip, which conforms to the
mouth during temperature readings. It is enhanced with beeper, memory and fever
alarm.The following instructions will cover your thermometer's features in further
detail.
What is a "Normal" Temperature?
Although the generally accepted "normal" temperature reading is 98.6 ° F(37.0°C),
temperature readings can vary from 97 ° F(36.1°C) to 99 ° F(37.2°C) and still may be
considered "normal". Variations in temperature can be attributed to activities such as
exercise, smoking, eating and drinking. Even time of day may influence your temper-
ature. For example, your temperature is lower in the morning than in the afternoon.
Other variations may be due to the location of the temperature reading. While the oral
temperature follows the guidelines previously described, a rectal temperature is gen-
erally 1.0 ° F(0.5°C) higher. Conversely, an axillary (under the arm) temperature will be
1.0 ° F(0.5°C) lower.
Features of Your Digital Thermometer
DIGITAL DISPLAY WINDOW
PROBE TIP
ON/OFF BUTTON
Cleaning Instructions
Before and after each use, clean the thermometer with a soft cloth and 70% isopropyl
alcohol diluted with water, or wash with COLD soapy water. An intact unit can be
submersed in water or alcohol. However, do not soak for an extended period of time.
1. The unit must never be sterilized by boiling, gas or steam autoclaves.
2. The use of any other solution or cleaning method beyond the above mentioned
may result in reliability problems with the thermometer and void your warranty.
How to Take Your Temperature
NOTE: Measurement time may vary based on the selected site.
1. Clean and disinfect the thermometer according to the instructions provided.
2. Apply a disposable probe cover to the clean, dry thermometer.
3. Determine whether the measurement site will be oral, rectal or underarm.
Switching Dual Scale
NOTE: To change between Celsius and Fahrenheit readings, hold the POWER
button down for 2 seconds until the "Lo" with an "M" displays and changes between
°F and °C. Press the POWER button again to turn the thermometer off.
Once the desired temperature is selected, press the POWER button (the
unit will beep and the backlight will turn on for about 3 seconds) to activate
the thermometer. This is the LCD display test, which ensures all parts of
the display are functioning properly.
The thermometer will display the last reading taken, followed by a self-test
temperature 98.6°F(37.0°C) for about 1 second. The display will show "Lo"
with a flashing °F(°C) indicating the thermometer is ready for measurement.
NOTE: If the temperature is less than 89.6°F(32.00°C), the LCD displays
"Lo" °F(°C). If the temperature is greater than 110°F(43.00°), the LCD
displays "Hi" F°(C°).
Taking an Oral Temperature
Approximate measurement time: 8-10 seconds
1. Using the diagram on the right, place the
probe tip under the tongue as near as
HEAT
POCKET
possible to the heat pocket. The diagram
also shows the temperature variables by
not placing the tip in the heat pocket
area.
NOTE: Drinking hot or cold fluids,
exercising, smoking or performing other
activities may raise or lower your
temperature. Therefore, it is important to
relax for approximately 5 minutes with your
mouth closed prior to taking a reading.
2. The current temperature is shown and the °F(°C) will continue to flash during the
reading.
3. When the peak temperature has been reached, the backlight will illuminate and
the °F(°C) will stop flashing. The thermometer will sound ten long beeps if the
temperature is below 100°F(37.8°C). If the temperature is above 100°F(37.8°C)
the unit will sound ten sets of three short beeps.
4. To turn the unit off, press the ON/OFF button. The unit will automatically shut off
after approximately ten minutes.
NOTE: The mouth must remain closed during the measurement for the most
accurate reading. Opening the mouth could result in an extended measurement time
and may affect the reading.
Taking an Axillary Temperature (under the arm)
Approximate measurement time: 10-20 seconds
1. Wipe the underarm with a dry towel.
DUAL SCALE
2. Place the probe tip under the arm so the tip is touching the skin with the
thermometer perpendicular to the body.
3. Position the arm across the chest so the probe tip is well covered by the arm. This
also ensures the probe is not affected by the room's air.
4. When the peak temperature has been reached, the backlight will illuminate and
the °F(°C) will stop flashing. The thermometer will sound ten long beeps if the
temperature is below 100°F(37.8°C). If the temperature is above 100°F(37.8°C)
the unit will sound ten sets of three short beeps.
5. To turn the unit off, press the ON/OFF button. The unit will automatically shut off
after approximately ten minutes.
NOTE: Axillary temperatures are generally 1.0°F(0.5°C) lower than oral readings.
Taking a Rectal Temperature
Approximate measurement time: 8 seconds
NOTE: Rectal temperatures are an appropriate and reliable method for infants and
small children. Otherwise, this method should only be used when it is impossible or
impractical to take an oral or axillary temperature.
1. After applying the disposable probe cover, apply a water-soluble lubricant to
the tip; do not use petroleum jelly.
2. Gently insert the probe a MAXIMUM of 1/2" into the rectum.
3. When the peak temperature has been reached, the backlight will illuminate and
the °F(°C) will stop flashing. The thermometer will sound ten long beeps if the
temperature is below 100°F(37.8°C). If the temperature is above 100°F(37.8°C)
BATTERY COVER
the unit will sound ten sets of three short beeps.
4. To turn the unit off, press the ON/OFF button. The unit will automatically power
down after approximately ten minutes.
NOTE: Rectal temperatures are generally 1.0°F(0.5°C) higher than oral readings.
Using Disposable Probe Covers
It is recommended to use the enclosed disposable probe covers to prevent cross
contamination. Additional probe covers can be purchased from your retailer or with
the order form provided.
General Care
1. The thermometer should only be used under the supervision of an adult.
2. Do not walk, run or talk during temperature taking.
3. Clean the thermometer before and after each use.
4. Store the unit in the protective case when not in use.
5. Do not bite the probe.
6. Do not store the unit where it will be exposed to direct sunlight, dust or humidity.
Avoid extreme temperatures.
7. Dropping or subjecting your thermometer to strong shocks should be avoided.
8. Do not attempt to disassemble the unit, except to replace the battery.
9. If ERR displays and measurement is not attainable, the unit must be replaced.
NOTE: Performance of the device may be degraded if: operated outside of stated
temperature and humidity range; stored outside of stated temperature and humidity
range; thermometer undergoes mechanical shock (drop); patient temperature is
below ambient temperature.
Changing the Battery
The battery in your digital thermometer needs to be replaced
when the "
the battery with a LR1130(AG10) or equivalent.
To replace the battery,
1. Remove the battery cover from the back of the thermometer
using a coin or small tool. Twist the cover counter-clockwise
and gently pry up.
2. Carefully remove the battery and insert the new battery with
the positive (+) side facing up.
3. Replace the battery cover and match up the arrows. Using a coin or small tool,
carefully twish the cover clockwise until it stops.
NOTE: Please properly dispose of the battery away from small children and heat.
Specifications
HEAT
98.8
o
F
98.8
o
F
POCKET
DISPLAY:
37.1
o
C
37.1
o
C
DISPLAY RESOLUTION:
MEASUREMENT RANGE:
98.4
o
F
98.4
o
F
ACCURACY:
36.9
o
C
36.9
o
C
AVERAGE MEASUREMENT TIME:
98.1
o
F
TONE:
36.7
o
C
97.9
o
F
97.9
o
F
36.6
o
C
36.6
o
C
97.7
o
F
36.4
o
C
MEMORY:
BATTERY:
BATTERY LIFE:
AUTOMATIC SHUT-OFF:
AMBIENT OPERATING TEMPERATURE:
STORAGE TEMPERATURE:
DIMENSIONS:
WEIGHT:
Specifications are subject to change without notice. Meets ASTM Standard E1112.
" symbol appears on the top of the display. Replace
Model: 15-878-000
Liquid Crystal Display
0.1°F (0.1°C)
90.0°F (32.0°C) – 109.9°F (42.9°C)
±0.2°F, 98.0°F – 102.0°F (±0.1°C, 37.0°C – 39.0°C)
Oral 8-10 seconds. Rectal 8 seconds. Axillary 10-20 seconds
Thermometer beeps when activated and deactivated. After the
measurement is complete, ten long beeps sound for
temperatures under 100°F (37.8°C). Ten sets of three short
beeps sound for temperatures above 100°F (37.8°C).
Displays last measured temperature
One, LR1130(AG10) or equivalent
Approximately 2 years
After approximately 10 minutes
°
°
50.0
F to 104.0
F (10.0°C – 40.0°C)
14.0°F – 140.0°F (-10.0°C – 60.0°C)
4-3/4" x 1-1/4" x 5/8"
0.6 ounces (16.2 grams)
©2008 MABIS Healthcare
LIMITED LIFETIME WARRANTY
MABIS Healthcare ('MABIS') guarantees that its MABIS Digital Thermometer will
be free from manufacturing defects under normal use for a period of one year from
the date of purchase subject to the following terms and conditions.
This warranty covers only normal use, and does not apply to use in any clinical or
commercial applications. This warranty does not cover batteries or other power
sources that may be provided with or used with the MABIS Digital Thermometer.
This warranty is voided if the MABIS Digital Thermometer product is misused or
abused in any manner.
If the MABIS Digital Thermometer fails to operate during the duration of the war-
ranty, return it postage prepaid to: MABIS Healthcare, Attn: Repair Department,
1931 Norman Drive South, Waukegan, IL 60085. MABIS will repair or replace the
defective unit at the option of MABIS Healthcare. Repair or replacement of the
defective unit, at MABIS' option, is the sole remedy under this warranty.
ANY IMPLIED WARRANTIES WHICH THE PURCHASER MAY HAVE ARE LIM-
ITED IN DURATION TO THE TIME THAT THE ORIGINAL CONSUMER PUR-
CHASER OWNS THE PRODUCT. Some states do not allow limitations or how
long an implied warranty lasts, so the above limitation may not apply to you.
This warranty constitutes MABIS' only responsibility and obligation to repair and/or
replace materials or components, or refund the purchase price. MABIS will not
be responsible for any indirect, incidental, special, consequential, or puni-
tive damages or other loss, including, but not limited to, damage to or loss of
other property or equipment and personal injuries, whether to purchaser or oth-
ers. MABIS shall in no event be liable to the purchaser for any amount in excess
of the cost of repair and/or replacement of the unit, or the purchase price of the
unit. Some states do not allow the exclusive or limitation of incidental or conse-
quential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights
which vary from state to state.
WARRANTY REGISTRATION DEPARTMENT
1931 NORMAN DRIVE SOUTH
THERMOMETER WARRANTY REGISTRATION
(MUST BE COMPLETED WITHIN 10 DAYS OF PURCHASE)
NAME:
ADDRESS:
CITY:
PURCHASED FROM:
CITY:
DATE PURCHASED:
MODEL PURCHASED: 15-878-000
USER INFORMATION (OPTIONAL)
K MALE
AGE OF YOUNGEST FAMILY MEMBER
K UNDER 6 MONTHS
K 1 - 3 YEARS
PROBE COVER ORDER FORM
CUT OUT AND MAIL TO:
Please send
#15-618-000 (100 probes per package). Enclosed is $5.00 per
package plus $3.00 for shipping and handling for each order.
PAYMENT METHOD (do not send cash):
Please ship to:
NAME:
ADDRESS:
CITY:
PHONE:
(
)
#MT-C19 04/08
NOTE: This order form is for shipments within the United States and
Canada.
CUT OUT AND MAIL TO:
WAUKEGAN, IL 60085
STATE:
ZIP:
STATE:
ZIP:
K FEMALE
AGE:
K 6 MONTHS - 1 YEAR
K 3 - 5 YEARS
K OLDER
MABIS HEALTHCARE
1931 NORMAN DRIVE SOUTH
WAUKEGAN, IL 60085
packages of disposable probe covers
Check
Money Order
STATE:
ZIP:

Advertisement

loading

Summary of Contents for MABIS 15-878-000

  • Page 1 MABIS shall in no event be liable to the purchaser for any amount in excess 4. To turn the unit off, press the ON/OFF button. The unit will automatically power of the cost of repair and/or replacement of the unit, or the purchase price of the down after approximately ten minutes.