Download Print this page
LockMasters LOCKONE LKM10K Operating Instructions

LockMasters LOCKONE LKM10K Operating Instructions

Push pull handle with a kaba mas x-10 and key override

Advertisement

Quick Links

Standard Key Override Escutcheon
for use on FIRE RATED DOORS
Key Override Escutcheon with
Light Indicator for use on
NON-FIRE RATED DOORS
2101 John C. Watts Dr.
Nicholasville, Ky 40356
800-654-0637 • 859-885-6041
www.lockmasters.com • www.LKM10K.com
LKM10KHOPINST
The Key Override Escutcheon
installation will vary depending on
the Fire Rating on the door.
The Light Indicator can NOT be
installed on Fire Rated Doors.
The Light Indicator can ONLY
be installed in the Key Override
Escutcheon on Non-Fire Rated
Doors.
Therefore, you will only see a "green"
light after the access control badge
has been accepted above the key
cylinder on Key Overrides installed
on Non-Fire Rated Doors.
Copyright © Lockmasters, Inc. Feb 2018
L
Shown with the Kaba Mas X10
Using Key Override
Operating Instructions for the
LKM10K Push Pull Handle Model
with a Kaba Mas X-10 and Key Override
ENTRY
Open the combination lock by
dialing the combination until the lock bolt
is retracted. The dial will come to a dead stop.
Note: See the manufacturers' operating/programming
instructions for dialing procedures and programming
features for the combination lock.
Leave the combination lock in the open position. (The lock
bolt for the combination lock is within the LKM10K and is not
the latch that can be seen from outside the lock).
If the door does not have secondary electronic access control
and the combination lock has been opened, The LKM10K
will remain locked until the key is inserted into the Key
Override cylinder and turned in either direction. With the
key turned the external lever handle can be turned up or
down to retract the deadbolt and open the door. The key
can be removed once the door is open and will relock once
the door closes and latches. Essentially the Key Override
can act as a manual access control.

Advertisement

loading

Summary of Contents for LockMasters LOCKONE LKM10K

  • Page 1 • www.LKM10K.com can be removed once the door is open and will relock once Using Key Override the door closes and latches. Essentially the Key Override can act as a manual access control. LKM10KHOPINST Copyright © Lockmasters, Inc. Feb 2018...
  • Page 2 Operating Instructions for the LKM10K Push Pull Handle Model with a Kaba Mas X-10 and Key Override If electronic access control is present – the combination lock bolt must be retracted first and then present the badge and/or PIN. After the access control badge has been accepted a green light above the key cylinder will illuminate as an indication that the lock is unlocked (If the Key Override Light Indicator is installed, see back page).