Technical Data - SWR ProGap S Operating Instructions Manual

Microwave barrier
Table of Contents

Advertisement

Operating Instructions
Mounting types
The ProGap S can be easily installed in the following
ways:
Screwing it into a G 1½-inch threaded connection,
using a DN 40 flange or
using a pipe clamp or other holding bracket.
Mounting with separating flange

9. Technical Data

Sensor
Housing: Stainless steel 1.4571
Material
Sensor-isolation: POM
Protective system
IP 65
As ProGap S Ex-sensor in DustEx-zone 20/22
Using in EX-Zones
and GasEx-zone 0/2 only with process-adapter
-20 ... + 80 °C
Process temperature
-20 ... +220 °C ( with process-adapter )
max. 1000 °C (with ceramic flange)
Ambient temperature
-20 ... +60 °C
max. 1 bar
Working pressure
max. 20 bar ( with process-adapter )
0 ... 4 m
Detection range
0 ... 18 m
> 18 m ( on demand )
Power supply
12 V DC powered by DIN Rail electronic
Power consumption
approx. 1.8 VA
Current consumption
max. 100 mA
Measuring frequency
K-Band 24.125 GHz (± 100 MHz)
Transmitting power
max. 5 mW
Transmitter: approx. 560 g
Weight
Receiver:
SWR engineering Messtechnik GmbH
Gutedelstraße 31 · 79418 Schliengen (Germany)
Fon +49 7635 82 72 48-0 · Fax +49 7635 82 72 48-48 · www.swr-engineering.com
EN 24/11/2015
Thread mounting
Mounting with pipe clamp
approx. 560 g
DIN Rail electronic
Power supply
Power consumption
Current consumption
Relay (max.)
• Voltage
• Current
• Capacity
Fall-delay time
Weight
Protective system
certificated
according to
A
B
24 V DC ± 10 %
3.5 W
120 mA at 24 V
250 V AC
1 A
60 W
0.25 ... 5 s (continuously adjustable)
approx. 172 g
IP 40
AT E X
10

Advertisement

Table of Contents
loading

Table of Contents