Technical Data - SWR Envea M-Sens 2 Operating Instructions Manual

Online moisture measurement for solids
Hide thumbs Also See for Envea M-Sens 2:
Table of Contents

Advertisement

13. Technical data

Sensor
Housing
Sensor surface
Ex-protection (optional)
Protection category
Material ambient temperature
Working pressure
Power consumption
Response time
Weight
Measuring range
Accuracy
Connection cable
Transmitter
Power supply
Power consumption
Current consumption
Protection category
Operating temperature
Dimensions
Weight
Interface
Cable glands
Cable cross section
Current output signal
Switched output measuring alarm
Digital inputs
Data protection
SWR engineering Messtechnik GmbH
Gutedelstraße 31 · 79418 Schliengen (Germany)
Fon +49 7635 827248-0 · Fax +49 7635 827248-48 · www.swr-engineering.com
PART OF THE ENVEA GROUP
EN 07/06/2018
Stainless steel 1.4571
Ceramic
Zone 0 (gas), Zone 20 (dust)
IP 67 according to EN 60529
0 ... +120 °C
Max. 10 bar
0.6 W
0.1 s
Approx. 1000 g
0 ... 65 % residual moisture (depending on material)
0.1 % absolutely in the calibrated measuring range
Shielded cable 4-wired, 0.25 mm
110 / 230 V AC (50 Hz) / 24 V DC
20 W / 24 V
Max. 1 A at 24 V
IP 65 according to EN 60529/10.91
-10 ... +45 °C
258 x 237 x 174 (W x H x D)
Approx. 2.5 kg
RS 485 / USB
3 x M16 (4.5 - 10 mm Ø)
0.2 - 2.5 mm² [AWG 24-14]
1 x 4 ... 20 mA (0 ... 20 mA), load < 500 W
Relay with two-way contact - max. 250 V AC, 1 A
2 inputs for active external control signals
Flash
2
27

Advertisement

Table of Contents
loading

Table of Contents