QuietCool QC TRI PRO-1.5X Owner's Manual page 14

Table of Contents

Advertisement

Figure 4.1B
Whole House Fan
5. Begin wiring the fan by opening up the handy box.
6. Take off the wire nuts within the handy box.
7. Unscrew the green ground wire. Detach the green ground wire from the power cord. Remove
the power cord and strain relief connector.
8. Re-attach the ground screw and wire to the handy box. Cut your green ground
wire in half and strip both sides. (see Figure 4.1B)
9. Install the included romex connector in the junction box and feed the 2 wire Romex through the
handy box.
10. Using the included wire nuts, tie the black wire and red wire together.
11. Tie the white neutral wires together.
12. Tie your bare copper wire and green ground wires together.
13. Carefully reinstall the handy box cover.
14
Tie All Ground & Bare Copper Wires Together
All White Common Wires Together
All Black Wires Together
2 Wire