Download Print this page

Schaller Messtechnik humimeter GE1 User Manual page 3

Floor screed moisture meter

Advertisement

Measuring procedure GE1 basic device
To switch on the instrument, press the
key for
three seconds.
After showing the logo, the measuring window
opens and the current measuring values are
displayed.
Now you can select the desired calibration curve
by pressing
or
. The calibration curves saved
in the device can be found in the list below.
Look for some representative positions that are suitable for monitoring the
floor screed moisture. The thickness of concrete in these places has to be at
least 30mm.
Please make sure that there are no pipes, electric cables or iron gratings in
this area. Metal objects within the measuring field of 30mm lead to incorrect
measuring values.
Before measuring, clean the measuring area with a broad scraper. The
measuring device has to rest on the concrete with its full surface without any
air space. The measuring area must not be polluted by grit.
Select the calibration curve that best fits your material to measure using the
arrow keys. For a list of material types and corresponding densities, please
see the chart below.
Please ensure that the measuring instrument has nearly the same
temperature than the material to measure.
Press the measuring instrument with downward measuring surface
with a pressure of approx. 4kg onto the cleaned measuring area. The
water content is displayed immediately.
The interpretation of the shown floor screed water content needs the
experience of the user, based on the recommendations of the floor screed
producer.
The thickness of floor screed can differ. The humimeter GE1 always
measures the supreme layer of 30 mm.
Version 1.0_en