6 Capacity/Charging problem

ACTIONS
• Make a general visual inspection for oxidation, corrosion or liquid damages.
No action is taken for liquid damaged telephone, send the unit according to local
company directive.
• Test the telephone with a fully charged battery. If necessary replace the Battery.
• Check the battery's condition and the battery's contact surface for oxidation or
• Make sure that the rubber gasket on the battery
• Check that the battery connector is free from dirt, oxidation, mechanical damage
• Check the system connector
If the fault still remains, send the unit according to local company directive.
corrosion
Fig
1. If necessary replace the Battery.
and that the battery connector pogo pins
necessary clean it.
Fig 1
Fig 4
4/00021-1/FEA 209 544/18.B
R250s Mechanical Trouble Shooting Instruction
Fig 2
Fig 3
are elastic. If necessary clean it.
Fig 4
for dirt, oxidation or mechanical damage. If
Fig 2
isn't damaged.
Fig 3
8