Troubleshooting - ONE OE-AC7000K-34 Installer Manual

Ac charger
Table of Contents

Advertisement

Charger Status State
Standby
Ready to
charge
Charging
Stop charging
Fault

9. Troubleshooting

Error
RelayDerate Relay over
Relay
OverTemp
INT Derate
INT
OverTemp
Leak Error
On, but no charger
plugged in.
Plugged in but not
charging.
Plugged in and charging
Charging has stopped,
charger is still plugged in
Error
Description
LED
Status
Without
temperature
red
warning
Relay over
Constantly
temperature
Red
error
Input
Without
terminal over
red
temperature
warning
Input
Constant
terminal over
red
temperature
error
Leakage
Constant
current
red
circuit error
Charge
Solution
Status
Normal Recover after relay tem-
perature is less than 95
degrees for continuous
500ms
Fault
Recover after relay
temperature is less than
60 degrees for
continuous 500ms or
unplug connector
Normal Recover after input
terminal temperature is
less than 95 degrees for
continuous 500ms
Fault
Recover after input
terminal temperature is
less than 60 degrees
for continuous 500ms or
unplug connector
Fault
Recover after the
circuit return to normal
22