Function Button Description (FND Display Window)

F. 1
Maximum Discharge
Time
F. 2
Complete removal of
ice in the reservoir
F. 3
Automatic ice
discharge function
F. 4
Initial water
subtraction function
F. 5
Automatic drain
function
F. 6
ICE + WATER
volume control
F. 7
UV LAMP time
adjustment
F. 8
Notify service period
setting
F. 9
Cumulative uptime
F. 10
Change temperature
unit
F. 11
Evaporation inlet
temperature display
F. 12
Evaporation outlet
temperature display
F. 13
Choose ice water
discharge method
① SOLENOID Maximum operating time adjustment function.
②3
rd
th
, 4
digits: 20 seconds (5 seconds ~ 30 seconds, Set Unit of one
second)
①This function can be entered in "OFF" state of ICE MAKING-OFF-WASH
switch.
②Press two buttons (WATER, ICE) simultaneously for 3 seconds and Button
part LED lights up.
③ Press the discharge lever for continuous operation of SOLENOID and the
motor. Keep 'ON' state.
① When ICE, WATER &ICE button is selected, ice is automatically emitted
for the set time.
② Automatic operation is not possible when OFF is set. (Manual operation)
③ Automatic discharge is performed for the set time of At01 ~ 99.
① It operates first when "ICE MAKING" switch is operated.
st
nd
② FND 1
, 2
digits (drain time) 30 seconds (oF ~ 99 seconds, Set Unit of
one second)
③ Water supply operation after drainage to high water level.
rd
th
④ FND 3
, 4
digits (number of repetitions) Standard: 3 times (1 ~ 9 times)
It operates when "ICE MAKING" switch is operated.
② FND 1
st
nd
, 2
digits (drain time): 2 seconds (oF ~ 9 seconds, Set Unit of one
second)
rd
th
③ FND 3
, 4
digits (drain interval): 1.0 hour (0.5 ~ 9.5 hours, every 30
minutes)
①1
st
nd
, 2
digits Ice time Default 5 seconds (up to 99 seconds)
rd
th
②3
, 4
digits Water time Default 5 seconds (up to 99 seconds)
st
nd
①1
, 2
digit lighting time Default 3minutes (99 minutes possible)
rd
th
②3
, 4
digits off time Default 1 hour (9 hours available)
① A.1.0 After using 10,000 hours, the corresponding mode LED blinks for 5
seconds (for the first 5 seconds during ice making)
② A.1.1 After using 11,000 hours, all LEDs blink for 5 seconds (1 hour cycle)
① The FND display is displayed in year, month, day, and hour, and is
displayed in order from right to left.
② Cumulative operation time of product is expressed in hour unit.
③ Calculation example: 12 months for 1 year, 30 days for 1 month, 24 hours
for 1 day.
Function of setting the unit of temperature in degrees Celsius or Fahrenheit
ordE : Discharge ice first and then discharge water
join : Simultaneous discharge of ice and water