23. Front panel user interface

The 630 series devices can be ordered with a detached front
panel user interface (HMI). An integrated HMI is available for 4U
high housing. The local HMI includes a large graphical
monochrome LCD with a resolution of 320 x 240 pixels (width x
height). The amount of the characters and the rows fitting the
view depends on the character size as the characters' width
and height may vary.
15 programmable alarm LEDs can indicate 45 alarms. The local
HMI offers full front panel user interface functionality with the
GUID-5CFD3446-A92F-4A5F-B60D-90025DCFDC61 V2 EN
Figure 11.
Local user interface

24. Mounting methods

The mounting methods for the PML630 device are identical to
the 630 series protection relays. With appropriate mounting
accessories, the standard case for the 630 series protection
relays can be flush-mounted, semi-flush-mounted or wall-
mounted. A detachable HMI is intended for optimized mounting
in a medium-voltage metal-clad switchgear, thus reducing
wiring between the low-voltage compartment and the panel
door. Furthermore, the protection relays can be mounted in any
standard 19" instrument cabinet with the 19" rack-mounting
accessories.
There are different kinds of mounting methods.
• Flush mounting
• Semi-flush mounting
• Overhead or ceiling mounting
• 19" rack mounting
• Wall mounting
• Door mounting of the local HMI, protection relay case
mounted in the low-voltage compartment of the
switchgear
For more information on different mounting options, see the
630 series installation manual 1MRS755958 and the quick
installation guide 1MRS757518.
36
menu navigation, menu views and operational data. In addition,
the local HMI is configured automatically using PCM600 (as a
part of the device configuration steps) to display the key load-
shedding single-line diagram. The single-line diagram view
displays the status of the critical circuit breakers like generator,
grid transformer circuit breakers, network circuit breakers (bus
couplers and equivalent tie feeder representation) and busbar
arrangements. Additional representation like load feeders,
generator and grid transformer can also be configured over and
above the key load-shedding single-line diagram.