senva TotalSense Series Navigation Manual

senva TotalSense Series Navigation Manual

Air quality sensor display navigation guide

Advertisement

Quick Links

Display Navigation Guide
TotalSense Series
Senva Sensors
9290 SW Nimbus Ave
Beaverton, OR 97008
Rev.
Release Date
0A
0B
6/10/2022
Copyright ©2022. All rights reserved. This document contains Senva Sensors proprietary
information and may not be reproduced or distributed without written permission.
154-0042-0B
By
Description of Change
NAK
Initial Release
NJS
Updates for engineering CI release
ECR
---
---
---

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TotalSense Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for senva TotalSense Series

  • Page 1 Beaverton, OR 97008 154-0042-0B Rev. Release Date Description of Change Initial Release 6/10/2022 Updates for engineering CI release Copyright ©2022. All rights reserved. This document contains Senva Sensors proprietary information and may not be reproduced or distributed without written permission.
  • Page 2: Table Of Contents

    Advanced Settings ......................15 Diagnostics ........................15 Air Quality Thresholds ..................................18 TVOC Molecular Weights ..................................19 See Also: 152-0401 TotalSense Installation Instructions 154-0043 TotalSense BACnet Protocol Guide 154-0044 TotalSense Modbus Protocol Guide Display Navigation Guide, TotalSense Series Page 2 of 19 154-0042-0B...
  • Page 3: Display Navigation

    Display Navigation Congratulations on installing your new Senva TotalSense Air Quality Sensor! This OLED Parameter Map assumes the first stage of installation is complete, with the TotalSense connected and powered. The OLED display should show the home screen when any button is pressed. If you see a lock icon, hold the up and down arrows for 5 seconds to unlock.
  • Page 4 To view comms, navigate to “view comms” in the main menu. To view current readings without configuring display, navigate to “view readings” in the main menu. Display Navigation Guide, TotalSense Series Page 4 of 19 154-0042-0B...
  • Page 5: Display Settings

    No value will be shown. Display> See center Lower Options described in display settings > Center. Air (default: CO2 if Right Quality is not an option for this corner. present) Display Navigation Guide, TotalSense Series Page 5 of 19 154-0042-0B...
  • Page 6 (default: high) Brightness Settings > Low, medium, Display> Adjust brightness Adjust value to increase or decrease brightness of screen high (default: of screen saver saver. low) Brightness Display Navigation Guide, TotalSense Series Page 6 of 19 154-0042-0B...
  • Page 7: Analog Parameters

    This value corresponds to the highest point on an Max current 0-20mA Output 1> analog scale. For a 0-20mA or 4-20mA signal, set to output for O2 (default 20mA) Max A 20mA. Display Navigation Guide, TotalSense Series Page 7 of 19 154-0042-0B...
  • Page 8 Default source setting for analog out 3 (if at least 3 of ‘source’ sensors are present) is first available sensor in this order: RH, Temp, slider. *PID output controls are only available on Analog output 1 or Analog output 3 for the comms+analog device. Display Navigation Guide, TotalSense Series Page 8 of 19 154-0042-0B...
  • Page 9: Air Quality Settings

    “Poor” rating. display Set the French Language of the When displaying the Air quality on the canter of the Language Air Quality main screen, this will English display (default) Display Navigation Guide, TotalSense Series Page 9 of 19 154-0042-0B...
  • Page 10: Source Parameters

    (minimum > Size size for analog 0.3-4.0, size is 0.3µm). For example, PM2.5 will show particle Range and display 0.3-10.0 count for particles sized 0.3-2.5µm. Display Navigation Guide, TotalSense Series Page 10 of 19 154-0042-0B...
  • Page 11: Rh Settings

    -40 to 122 scale for a temp reading. This will correspond to any Analog analog (default: 50 analog output that has temp selected as a source in Out Min Analog Parameters. Display Navigation Guide, TotalSense Series Page 11 of 19 154-0042-0B...
  • Page 12: Tvoc Settings

    Analog (default: 95 analog output that has temp slider selected as a source and display Out Max in Analog Parameters. This will not affect the slider resistive output. Display Navigation Guide, TotalSense Series Page 12 of 19 154-0042-0B...
  • Page 13: Relay Settings

    Turn-off Turn-off selection) Threshold value Threshold value 0-10,000 8.0% 800 PPM 7.0% 700 PPM 0-100% 60% RH 55% RH Temp* -40 - 122 TVOC 0-10000 4.0% 3.5% μg/m μg/m μg/m Display Navigation Guide, TotalSense Series Page 13 of 19 154-0042-0B...
  • Page 14: Pir Settings

    This applies to the “occupancy” BACnet active after (default: 10 Occupied and Modbus point as well as the output relay state, event min) Delay if set to PIR in Relay Settings. Figure 3: PIR Sensitivity Display Navigation Guide, TotalSense Series Page 14 of 19 154-0042-0B...
  • Page 15: Advanced Settings & Diagnostics

    Consult factory. Ready > CO2 zeros indicate Status no errors or warnings are present. 00001000 = Pressure No action necessary. Default value (101kPA) Compensation not applied is used for pressure compensation. Display Navigation Guide, TotalSense Series Page 15 of 19 154-0042-0B...
  • Page 16 No action necessary. Default value (25C) is compensation not applied used for temperature compensation. 10000000 = Pressure No action necessary. Default value (101kPA) compensation not applied is used for pressure compensation. Display Navigation Guide, TotalSense Series Page 16 of 19 154-0042-0B...
  • Page 17 00000010 = Sensor data Diagnostics binary. All Consult factory. error > Pressure zeros indicate Status no errors or warnings are 00000100 = Sensor not Consult factory. present. ready Display Navigation Guide, TotalSense Series Page 17 of 19 154-0042-0B...
  • Page 18: Air Quality Thresholds

    The average air quality is assigned based on the following thresholds. These thresholds can be adjusted in AV28 Good-fair and AV29 fair-poor. Good ≥ 75 b. 55 < Fair < 75 Poor ≤ 55 Display Navigation Guide, TotalSense Series Page 18 of 19 154-0042-0B...
  • Page 19: Tvoc Molecular Weights

    TVOC Molecular Weights Senva’s TVOC sensor uses an Ethanol reading to determine a raw TVOC value. Additionally, conversion from µg/m uses the molecular weight of Ethanol. To scale based on a different gas baseline, choose the appropriate gas from the list below and enter the scale factor in TVOC Settings.