Download Print this page

Use And Maintenance - Bertazzoni KPH XT Series Installation And User Manual

Wall-mounted chimney hood

Advertisement

Available languages

Available languages

on the upper chimney as shown in figure 2A.
Insert upper decorative flue inside the lower decorative flue and rest them on top of
the frame. Extract the upper flue up to the bracket and fix it with the screws B (Fig.3). To
transform the hood from a ducting version into a filtering version, ask your dealer for the
charcoal filters and follow the installation instructions.
• Filtering version:
The filters must be applied to the motor positioned inside the hood. They must be centred
by rotating them 90 degrees until they click into place (Fig. 7).

USE AND MAINTENANCE

• We recommend that the cooker hood is switched on before any food is cooked. We also
recommend that the appliance is left running for 15 minutes after the food is cooked, in
order to thoroughly eliminate all contaminated air. The effective performance of the cooker
hood depends on constant maintenance; the anti-grease filter and the active carbon filter
both require special attention.
filter: This is a suction system which offers improved perfor-
• The anti-grease BAFFLE
mance with respect to the classic aluminium filters. Its structure means it is able to retain
grease particles, thereby reducing noise to a minimum. It should be washed regularly
every 15 to 30 days in order to prevent the oil from leaking out; this may be done by hand
or using the dishwasher.
- After a few washes, colour alterations may occur. This does not give the right to claim
their replacement.
• The active carbon filters are used to purify the air that is sent back into the room and
its function is to mitigate the unpleasant odours produced by cooking.
- The non-regenerable active carbon filters (cod. 901612) must be replaced at least every
4 months. The saturation of the active charcoal depends on the more or less prolonged
use of the appliance, on the type of kitchen and on the frequency with which anti-grease
filter is cleaned.
• Clean the hood frequently, both internally and externally, using a cloth dampened
with denatured alcohol or neutral liquid detergents that are non abrasive.
• The lighting .system is designed for use during cooking and not for the prolonged general
lighting of the room. The prolonged use of the lighting system significantly decreases the
average duration of the bulbs.
• Attention: the non compliance with the hood cleaning warnings and with the replace-
ment and cleaning of the filters entails risk of fires. One therefore recommends keeping
to the suggested instructions.
• Replacing LED lamps (Fig.8)
The intervention of a specialised technician is necessary to replace them.
• Commands luminous (Fig.9) the key symbols are explained below:
A = LIGHT
B = OFF
C = SPEED I
- 11 -

Advertisement

loading