Configuring Parameters for Fan Cartridge Module

#CFG
If the start command
lines, the parameterization will fail. For a successful parameterization, the following sequence must be strictly
observed.
To enter a parameter for the fan cartridge module, proceed as follows:
1. Connect the fan cartridge module to any source using a Mini-USB cable.
The fan cartridge module opens a flash drive containing the
Config.txt
2. Open the
3. Ensure that
#CFG
is written in the first line of the file.
4. Add a line break directly behind
5. Add the parameter/s in capitals in the line below
6. Add a line break directly behind each parameter.
7. Delete everything that follows the entered parameter/s, including blanks and blank lines.
Config.txt
8. Save the
9. Manually power off the fan cartridge module.
10. Power on the fan cartridge module dule to restart the extender module.
The fan cartridge module starts automatically with the entered parameter.
Example
Fig. 47
Example Config.txt with Parameter
46
is missing or is written to the wrong place, or if parameters are not separated in extra
file in a text editor.
#CFG
.
file.
NOTICE
Config.txt
#CFG
(one line per parameter).
474-Add-on Modules
file.