Installation; Evap Pan Information - Hussmann TY3ECRC Installation & Operation Manual

End/island caseextended canopyround cornerself-contained
Table of Contents

Advertisement

Installation

Store Conditions
• Case is designed to operate at temperatures at either
75°F at 55% relative humidity or 80°F at 55% relative hu-
midity. Case must be kept in that environment to ensure
case performance and product safety.
• Do not position the case near an HVAC vent.
• Do not position the case near an entrance door. Outside
ambient conditions may have an adverse affect on the
refrigeration performance, a minimum of 15 ft clearance
is required from doors.
• Do not position the case tight against a ceiling or soffit.
A minimum clearance 10 ft above the unit is required
for proper condensing unit air circulation.
• Do not block case intake or exhaust vent panel (supplies
critical intake air flow to the compressor)
DANGER
DO NOT place Self Contained versions
of this case, having the electric evaporator pan,
underneath or adjacent to any flammable structure
or structure housing flammable merchandise!
Uncrating the Stand
Place the fixture as close to its permanent position as
possible. Remove the top of the crate. Detach the walls from
each other and remove from the skid. Unbolt the case from
the skid. The fixture can now be lifted off the crate skid. Lift
only at base of stand! See page 14 for the lift points.
Condensate Evaporator Pan Setup and Maintenance
Setup:
The merchandiser comes factory equipped with an Evaporator Pan, to which the drain pipes from the case feed
condensate water into the Evaporator Pan. This pan will turn on when the float switch level is triggered, evaporating any
drained water from the merchandiser. The evaporator pan is placed into a metal receiver. The metal receiver is there to
collect excess water that may overspill in case of (a) failure of the condensate pans or (b) store conditions being above
design specification causing more condensate water to be formed than expected.
Maintenance:
Care must be taken to ensure that the condensate pans operate properly at the store. These units are designed to oper-
ate at either 75°F ambient and 55% relative humidity(RH) or 80°F ambient and 55% RH. If stores are operating above
this condition, case performance will be severely affected. If such a condition is noted, Evaporator pan must be checked
periodically to see if excess water is being collected. If water has accumulated, water must be siphoned out of the receiv-
er. Care must be taken while performing this step. Unit power should be shut off for electrical safety. Once water has been
removed and metal receiver is dried out, unit power can be turned back on. Correct the store conditions and ensure
temperature and relative humidity are within stated parameters. Call a HVAC technician if the A/C is not working properly.
See pg 12. Figure 1
Do Not Install the Vented Panels of the
self-contained model against a wall or
other storage fixture
Located in the lower sides of the self-contained models are
vented panels. These panels allow air circulation to the
condensing unit. Blocking or restricting air circulation
through these panels can cause poor performance and
damage the refrigeration system.
Exterior Loading
These models have not been structurally designed to support
excessive external loading. Do not walk on case tops:
This could cause serious personal injury and damage to
the fixture.
It is the contractor's responsibility to install
case(s) according to local construction and
Leveling
A LEVEL CASE IS NECESSARY TO ENSURE
PROPER OPERATION AND WATER DRAINAGE.
11
ATTENTION
INSTALLER
health codes.