NOMINAL PIPE
DIAMETER (IN.)
1/2
3/4
1
1 1/4
1 1/2
Cubic Feet Per Hour Required =
NOTE: The cubic feet per hour listed in the table above must be greater than the cubic feet per hour of gas flow required by
the furnace. To determine the cubic feet per hour of gas flow required by the furnace, divide the input rate of the furnace by
the heating value (from gas supplier) of the gas.
GAS FLOW RATES
(CUBIC FEET PER HOUR)
TIME FOR
REVOLUTION OF GAS METER
ONE REVOLUTION
(SECONDS)
1
10
360
12
300
14
257
16
225
18
200
20
180
22
164
24
150
26
138
28
129
30
120
32
113
34
106
36
100
38
95
40
90
42
86
44
82
46
78
48
75
50
72
52
69
54
67
56
64
58
62
60
60
62
58
64
56

Gas Information

CAPACITY OF BLACK IRON GAS PIPE (CU. FT. PER HOUR)
FOR NATURAL GAS (SPECIFIC GRAVITY - 0.60)
10
20
30
130
90
75
280
190
150
520
350
285
1,050
730
590
1,600
1,100
890
Table 14. Gas Pipe Capaacities
CUBIC FEET PER
5
10
1,800
3,600
1,500
3,000
1,286
2,571
1,125
2,250
1,000
2,000
900
1,800
818
1,636
750
1,500
692
1,385
643
1,286
600
1,200
563
1,125
529
1,059
500
1,000
474
947
450
900
429
857
409
818
391
783
375
750
360
720
346
692
333
667
321
643
310
621
300
600
290
581
281
563
Table 15. Gas Flow Rates
LENGTH OF PIPE RUN (FEET)
40
50
65
55
130
115
245
215
500
440
760
670
Input To Furnace (Btu/hr)
Heating Value of Gas (Btu/Cu. Ft.)
GAS FLOW RATES
(CUBIC FEET PER HOUR)
TIME FOR
ONE REVOLUTION
(SECONDS)
66
68
70
72
74
76
78
80
82
84
86
88
90
92
94
96
98
100
102
104
106
108
110
112
114
116
118
120
60
70
80
50
45
40
105
95
90
195
180
170
400
370
350
610
CUBIC FEET PER
REVOLUTION OF GAS METER
1
5
10
55
273
545
53
265
529
51
257
514
50
250
500
49
243
486
47
237
474
46
231
462
45
225
450
44
220
439
43
214
429
42
209
419
41
205
409
40
200
400
39
196
391
38
191
383
38
188
375
37
184
367
36
180
360
35
176
353
35
173
346
34
170
340
33
167
333
33
164
327
32
161
321
32
158
316
31
155
310
31
153
305
30
150
300
29