SOFT TOUCH SENSOR BOARD TS6 AND TS7
INDICATOR LIGHTS
NOTE: TS-5 BOARDS,
LED6,7,8,9,14, AND 15
ARE ALL GREEN
LED9 (ORANGE): is on when START FROM
1
WELD SOL input is hight
LED15 (WHITE): is on when HEAD DOWN LIM.
2
SW. contact is closed
LED8 (BLUE): is on when RETRACT VALVE ON
3
input is high or RETR. FOOT SWITCH contact
is closed
LED14 (GREEN): is on when RETR. FOOT
4
SWITCH contact is closed
LED6 (YELLOW): is on when ELECTR. CLOSED
5
LIM. SW. contact is closed
LED7 (RED): is on when SELECT SWITCH INPUT
6
contact is closed
100MA FUSE for 24VIS isolated voltage; used for
7
outside switches
LED2 (ORANGE): 24VIS isolated voltage; used for
8
outside switches
LED5 (ORANGE): 24VDC used for electronic
9
circuitry on this board
LED3 (ORANGE): +15VDC
10
LED4 (ORANGE): -15VDC
11
LED1 (ORANGE): +5VDC
12
5
4
3
6
7
8
9
10
11
12
13
14
15
16
13
14
15
16
17
18
2
1
17
LED16 (WHITE): high gain amplifier is on
FOR AC UNITS: indicates that sensor input voltage
is under 300mV
For MFDC UNITS: this is the normal condition
LED17 (RED): K1 spurious operation relay
is energized
WINDOW TURNS RED when START FROM WELD
SOL. input voltage is high
LED13 (RED): OUTPUT N.O. CONTACT is
closed Contact closure tells control to start
weld sequence
JP5 IN "STD": LED will be off during standby and
turn on at continuity
JP5 IN "S2": LED will be on during standy, off after
SV input, and on when continuity is detected
LED512 (BLUE): OUTPUT N.O. CONTACT is open
JP5 IN "STD": this is the normal standby condition
JP5 IN "S2": this will be off until SV input, then
will be on until continuity is detected
WINDOW TURNS RED when RETRACT VALVE
ON input is high or RETR. FOOT SWITCH contact
is closed