Startup Procedure - Unitrol RST300-115-RIVET Manual

Soft touch for pneumatic riveters
Table of Contents

Advertisement

START-UP PROCEDURE
1.
Turn on power to the SOFT TOUCH control.
2.
The SOFT TOUCH annunciator panel should go through a test procedure and then
the READY LED should turn on solidly.
3.
If the READY LED does flashes slowly or quickly see the trouble shooting section in
this direction book.
4.
The system should be ready for operation. There is no customer calibration needed
now or ever.
5.
Turn the switch to TEST OPEN and the riveting mandrel will open.
UNSUCCESSFUL SEQUENCE
If continuity is not detected within the maximum time set on the DIPswitch, riveting mandrel
will not get to full force, will open, and the Detect Time Exceeded, Dress Riveting Mandrel
LED will light. Clean the riveting mandrel and try the sequence again. Or check to see if the
DIPswitch on the board is set to a long enough time to allow for the riveting mandrel to close.
16
| SOFT TOUCH FOR PNEUMATIC RIVETERS
SUCCESSFUL SEQUENCE
WITHOUT LIMIT SWITCH
1.
Foot switch control sends voltage to
terminal 9 (SV)
2.
START lights
Low Force solenoid valve (SVL) is
3.
energized, Low Force ON LED lights
Riveting mandrel close
4.
Continuity is detected and Continuity
5.
Detected LED lights
High Force solenoid valve (SVH) is
6.
energized, High Force ON LED lights

Advertisement