JOYTECH BM 92 Owner's Manual

Arm-type fully automatic digital blood pressure monitor

Advertisement

Quick Links

Owner's Manual
Arm-type Fully Automatic
Digital Blood Pressure Monitor
Model
Arm Type
Arm Type
Contents
Safety Notice ............................................................................
Unit Illustration ....................................................................... 06
Important Testing Guidelines ................................................. 08
Quick Start ................................................................................ 09
Unit Operation ......................................................................... 10
Battery
Installation
........................................................................
.................................................................................
..............................................................
................................................................................................. 15
.......................................................................................... 17
........................................................................................................ 17
........................................................................
..................................................................................
Low Battery Indicator............................................................................
Bluetooth connection.....................................................................................
Troubleshooting .........................................................................................
Blood Pressure Information .................................................... 23
Maintenance .............................................................................. 27
Specifications ............................................................................. 29
Warranty .................................................................................... 31
Electromagnetic Compatibility Information ......................... 32
BM 92
02
.........................................................
Contact Information
The lay operator or lay responsible or ganization should contact
the manufacturer or the representative of manufacturer.
-for assistance,if needed,in setting up,using or maintaining
the product,or
-to report unexpected operation or events.
Manufactured by JOYTECH Healthcare Co.,Ltd.
No.365, Wuzhou Road,Yuhang Economic Development Zone,
Hangzhou City,311100 Zhejiang,China
Email: info@sejoy.com
Telephone: +86-571-81957767
Fax: +86-571-81957750
Safety Notice
1
Thank you for purchasing the BM 92 Blood Pressure Monitor. The unit has been constructed
using reliable circuitry and durable materials. Used properly, this unit will provide years of
satisfactory use.
Indications for use: The Arm-type Fully Automatic Digital Blood Pressure monitors are
intended to measure blood pressure(systolic and diastolic) and pulse rate of adults and
adolescents over 12 years of age.
All functions can be used safely and values can be read out in one
10
LCD DISPLAY. Measurement position is on adult upper arm only.
11
The PATIENT is an intended OPERATOR.
15
Blood pressure measurement determined with this device are equivalent to those obtained
by a trained observer using the cuff/ stethoscope auscultation method, within the limits
prescribed by the Recognized Consensus Standard (IEC 80601-2-30) for electronic
sphygmomanometers.
17
Precautions to Ensure Safe, Reliable Operation
18
1. Do not drop the unit. Protect it from sudden jars or shocks.
18
2. Do not insert foreign objects into any openings.
19
3. Do not attempt to disassemble the unit.
4. Do not crush the pressure cuff.
20
5. If the unit has been stored at temperatures below 0 ℃, leave it in a warm place for
22
about 15 minutes before using it. Otherwise, the cuff may not inflate properly.
6. If the unit has been stored at temperatures above 40 ℃, leave it in a cool place for about
15 minutes before using it. Otherwise, the cuff may not inflate properly.
7. Do not store the unit in direct sunlight, high humidity or dust.
8.To avoid any possibility of accidental strangulation, keep this unit away from children
and do not drape tubing around your neck.
9.Ensure that children do not use the instrument unsupervised; some parts are small
enough to be swallowed.
10.Some may get a skin irritation from the cuff taking frequent readings over the course
of the day, but this irritation typically goes away on its own after the monitor is removed.
Document No.:
XXXXXXXXXX
Version:Z
Date of Issue:XXXXXX
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BM 92 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for JOYTECH BM 92

  • Page 1: Table Of Contents

    Contents Safety Notice Safety Notice ................Thank you for purchasing the BM 92 Blood Pressure Monitor. The unit has been constructed Unit Illustration ............... 06 using reliable circuitry and durable materials. Used properly, this unit will provide years of Important Testing Guidelines ..........08 satisfactory use.
  • Page 2: Safety Notice

    18. Do not disassemble the unit or arm cuff. Do not attempt to repair. registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by JOYTECH 19. Use only the approved arm cuff for this unit. Use of other arm cuffs may result in Healthcare Co.,Ltd.
  • Page 3: Important Testing Guidelines

    10. Do not use this blood pressure monitor if the device is damaged. Owner's Manual Arm-type Fully Automatic Digital Blood Pressure Monitor BM 92 Model Any blood pressure recording can be affected by the following factors Arm Type 1. The position of the subject, his or her physiologic condition;...
  • Page 4: Unit Operation

    Unit Operation Unit Operation System Settings 1. Time/Date setting First to electricity, battery installed, normal blood pressure monitor for power self-checking, if the battery power is insufficient, the screen shows "LO" error code and flashing. After the month of determining, into the day set patterns, in the meantime, display, 0.5 seconds icon will flash once, press the keys into the Λ...
  • Page 5: Applying The Arm Cuff

    Unit Operation Unit Operation Applying the Arm Cuff 1. Firmly insert air plug into opening located on behind side of monitor unit. 2. With sticky nylon section facing outward, insert end of cuff underneath metal ring of cuff 3. Fasten cuff about 1-2cm (0.4-0.8'') above the elbow joint.
  • Page 6: Low Battery Indicator

    Unit Operation Unit Operation Bluetooth requirements Note: Memory cannot be recovered once it has been deleted. Wireless communication The monitor requires a device with: Frequency range : 2.4 Ghz (2400-2483.5 MHz) If you want to delete the other set of memories, please user memory group set up in front of the boot, .
  • Page 7: Blood Pressure Information

    WHO Blood Pressure Classification Indicator Blood Pressure The BM 92 is equipped with a classification indicator based on established guidelines from the World Health Organization. The chart below (color coded on monitor unit) Blood pressure is the force of blood pushing against the walls of arteries. It is typically indicates test results.
  • Page 8: Maintenance

    10.No service and maintenance while it is in use and maintenance only be performed by service personnel. Service and maintenance require parts, repair, technical support will be provided. Specifications Specifications Product Description Arm-type Fully Automatic Blood Pressure Monitor Operating Environment 800hPa~1060hPa Pressure BM 92 Temperature: Model (-13 ~131 ℃ ℃ ℉ ℉...
  • Page 9: Warranty

    Warranty Electromagnetic Compatibility Information The device satisfies the EMC requirements of the international standard IEC 60601-1-2. The requirements are satisfied under the conditions described in the The Blood Pressure Monitor is guaranteed for 2-year from the date of purchase. If the table below.
  • Page 10 Electromagnetic Compatibility Information Electromagnetic Compatibility Information Table 3 Table 4 Guidance and declaration of manufacturer-electromagnetic immunity Recommended separation distances between portable and mobile RF communications equipment and the device Nowadays, many RF wireless equipments have being used in various healthcare The device is intended for use in an electromagnetic environment in which locations where medical equipment and/or systems are used.

Table of Contents