Download Print this page

JOYTECH DBP-1333b Owner's Manual

Arm-type fully automatic digital blood pressure monitor

Advertisement

Quick Links

Owner's Manual
Arm-type Fully Automatic
Digital Blood Pressure Monitor
Model
Arm Type
Contents
Safety Notice ...............................................................
Unit Illustration
.........................................................
Important Testing Guidelines
Quick Start ................................................................. 10
Unit Operation ...........................................................
Battery Installation ..................................................
System Settings ........................................................
Applying the Arm Cuff ............................................. 14
Testing ..................................................................... 15
Power Off ................................................................
Last 3 Tests Average
.......... ....................................... 19
Memory Check ...................................................... .
Memory Deletion .....................................................
Low Battery Indicator .............................................
Bluetooth requirements
Troubleshooting ......................................................
Blood Pressure Information
Blood Pressure Q&A
................................................... 2
Maintenance
............................................................... 2
Specifications
.............................................................
Warranty .................................................................... 3
Electromagnetic Compatibility Information .............. 3
DBP-1333b
..................................... 0
...........................................
........................................ 2
Contact Information
The lay operator or lay responsible or ganization should contact
the manufacturer or the representative of manufacturer.
-for assistance,if needed,in setting up,using or maintaining
the product,or
-to report unexpected operation or events.
Manufactured by JOYTECH Healthcare Co.,Ltd.
No.365, Wuzhou Road,Yuhang Economic Development Zone,
Hangzhou City,311100 Zhejiang,China
Email: info@sejoy.com
Telephone: +86-571-81957767
Fax: +86-571-81957750
1
Safety Notice
02
Thank you for purchasing the DBP-1333b Blood Pressure Monitor. The unit has been constructed
0
6
using reliable circuitry and durable materials. Used properly, this unit will provide yeas of
9
satisfactory use.
Measure blood pressure(systolic and diastolic)and pulse rate of adults and adolecents age
1
1
12 through 21years of age. All functions can be used safely and values can be read out in one
LCD DISPLAY. Measurement position is on adult upper arm only.
11
The PATIENT is an intended OPERATOR.
12
Blood pressure measurement determined with this device are equivalent to those obtained
by a trained observer using the cuff/ stethoscope auscultation method, within the limits
prescribed by the Recognized Consensus Standard (IEC 81060-2-30) for electronic
sphygmomanometers.
18
Precautions to Ensure Safe, Reliable Operation
20
1. Do not drop the unit. Protect it from sudden jars or shocks.
2. Do not insert foreign objects into any openings.
21
3. Do not attempt to disassemble the unit.
21
4. Do not crush the pressure cuff.
5. If the unit has been stored at temperatures below 0
23
about 15 minutes before using it. Otherwise, the cuff may not inflate properly.
24
6. If the unit has been stored at temperatures above 40
15 minutes before using it. Otherwise, the cuff may not inflate properly.
5
7. Do not store the unit in direct sunlight, high humidity or dust.
8
8.To avoid any possibility of accidental strangulation, keep this unit away from children
and do not drape tubing around your neck.
9
9.Ensure that children do not use the instrument unsupervised; some parts are small
31
enough to be swallowed.
10.Some may get a skin irritation from the cuff taking frequent readings over the course
3
of the day, but this irritation typically goes away on its own after the monitor is removed.
4
Document No.:JDBP-3804-050
Version: Z
Date of Issue: 2018.12
2
C, leave it in a warm place for
o
C, leave it in a cool place for about
o

Advertisement

loading
Need help?

Need help?

Do you have a question about the DBP-1333b and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for JOYTECH DBP-1333b

  • Page 1 Fax: +86-571-81957750 Contents Safety Notice Safety Notice ............... Thank you for purchasing the DBP-1333b Blood Pressure Monitor. The unit has been constructed Unit Illustration ............using reliable circuitry and durable materials. Used properly, this unit will provide yeas of Important Testing Guidelines ........
  • Page 2 21. Do not use the device near strong electrical or electromagnetic fields generated by cell registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by JOYTECH phones or other devices, they may cause incorrect readings and interference or become Healthcare Co.,Ltd.
  • Page 3 Unit Illustration Unit Illustration Contents Arm Cuff Medium size cuff (fits arm circumference: 22.0 cm -36.0 cm). Owner's Manual Arm-type Fully Automatic Digital Blood Pressure Monitor DBP-1333b Model Arm Type 2.Owner's Manual Air Tube Arm Cuff Air Plug 1.Monitor Unit If air is leaking from the arm cuff, replace the arm cuff with a new one.
  • Page 4 Important Testing Guidelines Unit Illustration Battery Installation System Settings Slide battery cover off as indicated by arrow. With power off, press "SET" button to activate System Settings. The Memory Group icon Install 4 new AA alkaline batteries according to polarity. flashes.
  • Page 5 Unit Operation Unit Operation 2. Pressurization Testing The unit will automatically inflate to the proper pressure value and stop inflating. 1. Power On During this time,please keep quiet. Press and hold "START/STOP" button to turn the unit on. The LCD screen will appear for one second as unit performs a quick diagnosis.
  • Page 6 Unit Operation Unit Operation Memory Check Last 3 Tests Average With power off,you may check past test results by using the "M" button. The most recent test result and oldest test result in memory can be viewed by pressing With power off,press the "M" button to activate screen display. After the unit performs and holding the "M"...
  • Page 7 Troubleshooting Bluetooth connection Using for the first time Problem Possible Cause Solution 1. Download the free “JOYTECH healthcare” App: On your mobile phone or table Firmly reposition cuff Cuff is too tight or not go to www.sejoy.com. approximately 1-2cm 1/2"...
  • Page 8 Blood Pressure Information Blood Pressure Q&A What is the difference between measuring blood pressure at home or at a professional Health Reminder healthcare clinic? Hypertension is a dangerous disease that can affect the quality of life. It can lead Blood pressure readings taken at home are now seen to give a more accurate account as to a lot of problems including heart failure, kidney failure, and cerebral hemorrhaging.
  • Page 9 Specifications Product Description Arm-type Fully Automatic Blood Pressure Monitor Temperature: ℃ ℃ ℉ ℉ -25 ~70 (-13 ~158 ) DBP-1333b Model Storage Environment Humidity ≤93% RH Display LCD Digital Display Size:102.1mm×68.9mm (4.02" x 2.71") Classification: Internal Powered Equipment,Type BF . Cuff is the Applied Part...
  • Page 10 Electromagnetic Compatibility Information Electromagnetic Compatibility Information Table 2 Table 3 Guidance and declaration of manufacturer-electromagnetic immunity Guidance and declaration of manufacturer-electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The device is intended for use in the electromagnetic environment The customer or the user of the device should assure that it is used in such an environm- specified below.