Electrical Safety Guidelines; Esd Safety Guidelines - Nokia ONT Product Manual

Hide thumbs Also See for ONT:
Table of Contents

Advertisement

ETSI ONT safety guidelines

Electrical safety guidelines

• This device must accept any interference, including interference that may cause undesired
operation of the device.
CAUTION
Service Disruption
To satisfy IC RF exposure requirements, a separation distance of 20 cm or more should be
maintained between the antenna of this device and persons during device operation. To ensure
compliance, operations at closer than this distance is not recommended.
Les antennes installées doivent être situées de facon à ce que la population ne puisse y être
exposée à une distance de moin de 20 cm. Installer les antennes de facon à ce que le personnel
ne puisse approcher à 20 cm ou moins de la position centrale de l' antenne. La FCC des états• unis
stipule que cet appareil doit être en tout temps éloigné d'au moins 20 cm des personnes pendant
son functionnement.
2.3 Electrical safety guidelines
This section provides the electrical safety guidelines for the ONT equipment.
Note: The ONTs comply with the U.S. National Electrical Code. However, local electrical
authorities have jurisdiction when there are differences between the local and U.S. standards.
The ONTs comply with BS EN 61140.
2.3.1
Power supplies
The use of any non-Nokia approved power supplies or power adapters is not supported or
endorsed by Nokia. Such use will void any warranty or support contract with Nokia. Such use
greatly increases the danger of damage to equipment or property.
2.3.2
Cabling
The following are the guidelines regarding cables used for the ONT equipment:
• All cables must be approved by the relevant national electrical code.
• The cables for outdoor installation of ONTs must be suitable for outdoor use.
• POTS wiring run outside the subscriber premises must comply with the requirements of local
electrical codes. In some markets, the maximum allowed length of the outside run is 140 feet (43
m). If the outside run is longer, NEC requires primary protection at both the exit and entry points
for the wire.
2.3.3
Protective earth
Earthing and bonding of the ONTs must comply with the requirements of local electrical codes.

2.4 ESD safety guidelines

The ONT equipment is sensitive to ESD. Operations personnel must observe the following ESD
instructions when they handle the ONT equipment.
26
3FE-49441-ABAA-TCZZA
Nokia ONT
June 2021
Issue 1