Product Diagram; Specifications - Adamson A40 User Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

Product Diagram

5
9
7
1. Control Panel
2. Air Vents
3. Castors
Specications
Model
Cooling Capacity
Heating Capacity
Refrigerant
Permissible Excessive
Operating Pressure
Max Allowable Pressure
Weight
Rated Voltage
Rated Frequency
Application area
8
4
4. Exhaust outlet
5. Upper Drain Outlet
6. Air inlet
A40
Standard
7000 Btu/h (2.05kW)
Rating
Conditions
7000 Btu/h (1.8kW)
R290/140g
Discharge 2.6Mpa
Suction 1.0 MPa
Discharge 3.2 Mpa
Suction 1.2 MPa
20.5 kg
220-240 V
50 Hz
10-20 m²
4
6
7. Bottom Drain Outlet
8. Dust Filter
9. Power Supply
Cooling
Current
Heating
Cooling
Input
Heating
Cooling
Rated current
Heating
Cooling
Rated Input
Heating
Protection Class
Dimensions
Noise level
Dehumidification
1
2
3
3.5 A
3.5 A
785 W
782 W
3.5 A
4.0 A
785 W
890 W
IP20
330 x 704 x 292 mm
65 dB (A)
0.8 L/H

Advertisement

Table of Contents
loading

Related Products for Adamson A40

Table of Contents