Operation In Static And Dynamic Mode - Siemens SIMATIC RF200 System Manual

Rfid systems
Hide thumbs Also See for SIMATIC RF200:
Table of Contents

Advertisement

Planning an RF200 IO-Link system
4.1 Fundamentals of application planning
4.1.5

Operation in static and dynamic mode

Operation in static mode
If working in static mode, the transponder can be operated up to the limit distance (S
transponder must then be positioned exactly over the reader:
Figure 4-4
In static operation, the dwell time tv can be of any length (depending on the application). The
dwell time must be sufficiently long to allow communication with the transponder to be
completed.
Note
Note that in a metallic environment the values for the limit distance are reduced.
Operation in dynamic mode
Working in dynamic mode is not recommended for the RF200 IO-Link.
See also
Field data of transponders and readers (Page 25)
20
Operation in static mode
SIMATIC RF200 IO-Link
System Manual, 03/2012, C79000-G8976-C276-01
). The
g

Advertisement

Table of Contents
loading

Table of Contents