Device Description - Dimplex ZWU 06E Installation And Operating Instructions Manual

Central control unit with timer function
Table of Contents

Advertisement

Device description

The ZWU 06E central control unit controls the charging of an underfloor
storage heating system and/or the charging of storage heaters according
to outdoor temperature, adjusters and control signals.
The basic design of the control unit has the basic functions of a central
control unit as set out in DIN EN 50350. It has the following features:
• Charging according to outdoor temperature,
• The ability to process charge release signals from the distribution
network operator (with/without timer function),
• The ability to output the charge release and the set charge rate to the
storage heaters and underfloor charge controllers,
• Timer function for forward, backward and spread control,
• Priority and secondary use of actual service release periods for low
and high tariffs,
• For optional connection to older external sensors, too.
Depending on the unit type connected downstream, an AC and a DC
output are available for the control signal.
Scope of supply
− ZWU 06E central control unit
− NTC external sensor with 3 m connection cable
− Installation and operating instructions
− Safety notes