Hach BioTector B3500 Basic User Manual

Online toc analyzer

Advertisement

Quick Links

DOC023.53.90740
BioTector B3500 Online TOC Analyzer
BASIC USER MANUAL
6/2018, Edition 1

Advertisement

Table of Contents
loading

Summary of Contents for Hach BioTector B3500

  • Page 1 DOC023.53.90740 BioTector B3500 Online TOC Analyzer BASIC USER MANUAL 6/2018, Edition 1...
  • Page 3: Table Of Contents

    Table of Contents SECTION 1 SAFETY PRECAUTIONS ................. 4 ............4 NFORMATION AND AFETY IGNS USED IN THE ANUAL ............5 RECAUTIONARY ABELS TTACHED TO THE NSTRUMENT ............6 ERTIFICATION ARKS TTACHED TO THE NSTRUMENT ..................7 OTENTIAL YSTEM AFETY AZARDS 1.4.1 Ozone and Toxicity ..........................
  • Page 4: Safety Precautions

    Section 1 Safety Precautions Please read this manual before unpacking, setting up, or operating the BioTector. BioTector should only be used by qualified trained staff and for the purpose it is intended for. Do not use or install this equipment in any way other than the methods specified in this manual. The procedures and methods described in this manual are based on assuming the user have basic, fundamental background on electronics, chemistry and analyzer equipment.
  • Page 5: Precautionary Labels Attached To The Instrument

    Precautionary Labels Attached to the Instrument The labels and tags attached to the instrument are summarized below. Please read all labels and tags attached to the instrument. If not observed, personal injury or damage to the instrument could occur. This symbol, when displayed on the instrument, indicates that the user must gather the necessary operation and/or safety information given in the instruction manual.
  • Page 6: Certification Marks Attached To The Instrument

    Electrical equipment marked with this symbol may not be disposed of in European domestic or public disposal systems. Return old or end-of-life equipment to the manufacturer for disposal at no charge to the user. Certification Marks Attached to the Instrument The standard certification marks attached to the instrument and their meanings are summarized below.
  • Page 7: Potential System Safety Hazards

    Potential System Safety Hazards The potential safety hazards, which are associated with a running BioTector system, are as follows: Electrical hazards • • Potentially hazardous chemicals Oxygen gas and components generating Ozone gas • Maintenance and operation should not be carried out unless personnel have been fully trained in the operation of the BioTector.
  • Page 8: Ozone And Toxicity

    Ozone and Toxicity 1.4.1 Ozone is found in gaseous form as a natural ingredient of the earth's atmosphere. Some of the chemical and physical properties of ozone are as follows: Terms Properties of Ozone (O Molecule Weight 47.9982 g/g-mol Boiling Point -119 ±...
  • Page 9: General Safety Precautions

    General Safety Precautions Please pay attention to all caution, warning and danger statements at all times. Non-observance of the safety instructions can result in serious personal injury, death or damage to the equipment. Therefore observe the following: Only engineers trained by the manufacturer should carry out maintenance on the BioTector. ...
  • Page 10: Electrical And Burn Precautions

    1.5.1 Electrical and Burn Precautions BioTector contains electrical components operating under high voltages. Contact may result in electric shock and severe or fatal injury. DANGER During system installation, maintenance or servicing: Isolate the system power lines before starting any work in the electronic enclosure. •...
  • Page 11: Carrier Gas And Exhaust Gas Precautions

    1.5.2 Carrier Gas and Exhaust Gas Precautions BioTector uses oxygen (O ) gas as the carrier gas during its operation. The oxygen gas must be free of carbon dioxide (CO ) and nitrogen (N ) gases. The average rate of oxygen consumption in BioTector is 29 l/h (483 ml/min).
  • Page 12: Chemical Precautions

    1.5.3 Chemical Precautions A number of chemicals and compounds to be used with BioTector are listed in Section 6 Reagents and Calibration Standards. Some of these compounds are harmful, corrosive, acidic and oxidizing. Appropriate precautions must be taken when handling these chemicals or solutions prepared from these chemicals.
  • Page 13: Sample Stream Precautions

    1.5.4 Sample Stream Precautions The user is responsible to establish the potential hazard associated with each sample stream. Necessary precautions must be taken, to avoid physical contact with any harmful sample stream, which may contain chemical or biological hazards. System components and their composition, which come in contact with the sample liquid and possible volatile gases from the sample, are tabulated in table 1 below.
  • Page 14: Précautions Relatives Aux Échantillons

    1.5.4 Précautions relatives aux échantillons L’usager assume la responsabilité d’établir le danger possible que représente chaque échantillon. Il est essentiel de prendre les précautions voulues afin d’éviter le contact physique avec tout échantillon nocif qui pourrait présenter un danger chimique ou biologique. Le tableau 1 ci-dessous présente les composants de l’analyseur (et leur composition) qui entrent en contact avec l’échantillon liquide et les éventuels gaz volatiles émanant de l’échantillon.
  • Page 15: Operator's Manual

    Section 2 Operator’s Manual 2.1 Software Screens and Software Menu Diagram The BioTector is equipped with a built-in microprocessor, which has been programmed to enable the user to control the instrument using just six buttons of its membrane keypad. By pressing the appropriate button, the user can move through the various levels of the software menu.
  • Page 16 Software Menu Diagram Page 16...
  • Page 17: Startup State

    2.1.1 Startup State When the BioTector is powered up, its LCD screen will automatically display the Analysis Data screen after a delay of 60 seconds. By pressing the ESCAPE key the user moves from the Analysis Data screen to the Analysis Graph screen. Pressing the ENTER key on the Analysis Graph screens brings the user back to the Analysis Data screen.
  • Page 18: Analysis Data Screen

    2.1.3 Analysis Data Screen B I O T E C T O R R U N N I N G 0 9 : 1 7 : 2 8 1 2 - 0 9 - 0 2 0 9 : 1 3 : 0 2 1 2 - 0 9 - 0 2 R E A C T I O N S T A R T...
  • Page 19: Analysis Graph Screen

    2.1.4 Analysis Graph Screen 1 0 1 . 5 [ k P a ] 0 9 : 1 7 : 2 8 1 2 - 0 9 - 0 2 T I C m g u 1 2 . 4 9 5 6 C O 2 T O C m g u 1 5 6 .
  • Page 20: Select Level Menu

    2.1.6 Select Level Menu S E L E C T L E V E L 0 9 : 1 7 : 2 8 1 2 - 0 9 - 0 2 1 < O P E R A T I O N C A L I B R A T I O N M A I N T E N A N C E The Select Level screen allows the user to access the operation, calibration and maintenance menus.
  • Page 21: Operation Menu

    Operation Menu Operation Menu Diagram Operation menu allows the user to start and stop the analyzer. Menus related to system operation are also accessed using this menu. 2.2.1 Start Stop The user can Start or Stop the BioTector using the Start Stop menu. 1.
  • Page 22 2. Start. This function starts the BioTector. When BioTector is started, the multi-stream operation sequence (if programmed) is reset. BioTector performs Ozone Purge, Pressure/Flow Test, Reactor Purge and Analyzer Purge sequences automatically before starting its analysis. • Ozone Purge sequence purges any residual ozone through the ozone destructor. Pressure/Flow Test sequence confirm that there is no gas leak and there is no gas flow •...
  • Page 23: Reagents Setup

    2.2.2 Reagents Setup This menu allows the user to access the Reagent menus. 1. Install New Reagents. Menu used to install and prime the reagents in the BioTector. Any “85_Reagents Low” and “20_No Reagents” warnings and notifications can also be reset in this menu. 2.
  • Page 24: Purge Reagents & Zero

    When all or the necessary reagents have been confirmed to be connected and reset in this menu, and when Start New Reagent Cycle is selected, the Install New Reagents cycle will be executed. It is the responsibility of the user to make sure that all reagent volumes are programmed correctly in Reagents Monitor menu, the reset of the reagents monitoring are carried out correctly in Install New Reagents menu and finally if necessary the Zero Calibration cycle is activated either with the Start New Reagent Cycle function in Install New Reagents menu or with the Run Zero Calibration function in Zero Calibration menu.
  • Page 25: Manual Program Menu

    2.2.4 Manual Program Menu M A N U A L P R O G R A M 0 9 : 1 7 : 2 8 1 2 - 0 9 - 0 2 1 < R U N A F T E R N E X T R E A C T I O N R U N...
  • Page 26: Reaction Archive Screen

    2.2.5 Reaction Archive Screen The Reaction Archive holds information on TIC, TOC, TC, VOC (in mgC/l), COD, BOD (in mgO/l), Drinking Water parameters (REMOVAL in %, and RESULT in FAIL/PASS condition), stream valve, reaction range, start time and related analysis information for the last 9999 reactions. If the archive is full, then every new reaction overwrites the oldest one in the archive.
  • Page 27: Time & Date Menu

    2.2.7 Time & Date Menu This menu allows the system time and date to be set by the user. To change the system time or date (hours, minutes, seconds, day, month and year), press the ENTER key, enter the new time and date and press the ENTER key again.
  • Page 28: Calibration Menu

    Calibration Menu Calibration menu allows the user to calibrate the analyzer. Zero and Span Calibration menus allow the user to run the zero and span calibration cycles for a single range or for all system ranges available. Calibration Menu Diagram ENTER PASSWORD CALIBRATION ZERO CALIBRATION...
  • Page 29 1. The Zero Adjust settings for each range are updated automatically by the system using the un- calibrated TOC measurement (not the results seen on the LCD screen). If a Zero Check is used to check the zero offset, the suggested values are shown in brackets “[ ]” next to the actual Zero Adjust settings.
  • Page 30: Span Calibration

    2.3.2 Span Calibration S P A N C A L I B R A T I O N 0 9 : 1 7 : 2 8 1 2 - 0 9 - 0 2 1 < T O C S P A N A D J U S T 1 .
  • Page 31 4.-6. TIC Span Adjust. This menu item allows the user to set the TIC span adjust factors manually for each range as described for TOC Span Adjust above. 10. Run Span Calibration. This function starts the Span Calibration cycle. The span calibration reactions are run at a single range programmed by the RANGE in this menu below.
  • Page 32 20. TC Cal Std. In VOC systems, the sum of the TIC and TOC Calibration Standard solution is displayed as TC Calibration Standard. When TOC Calibration Standard is programmed as 0.0mgC/l, and when a concentration of TIC Calibration Standard is programmed above, BioTector displays the TC Calibration Standard as 0.0mgC/l on purpose.
  • Page 33 DOC012.97.80506 User Guidance for EMC Class A Equipment 업무용을 위한 EMC 등급 A 장치에 대한 사용자 지침 사용자안내문 A급 기기 (업무용 방송통신기자재) 이 기기는 업무용(A급) 전자파적합기기로서 판매자 또는 사용자는 이 점을 주의하시기 바라며, 가정외의 지역에서 사용하는 것을 목적으로 합니다.
  • Page 34 This document contains information which is only required for the export of this instrument into the People’s Republic of China. 本手册只包含出口到中华人民共和国的仪器的必要信息。 Statement on China "Management Methods for the Restriction of the Use of Hazardous Substances in Electrical and Electronic Products”, Ministry of Information Industry Order #39.
  • Page 36 (800) 227-4224 (U.S.A. only) Tel. +41 22 594 6400 Fax +49 (0) 2 11 52 88-210 Fax (970) 669-2932 Fax +41 22 594 6499 info-de@hach.com orders@hach.com www.de.hach.com www.hach.com © Hach Company / Hach Lange GmbH, 2018. All rights reserved. Printed in Ireland.

Table of Contents