Industrial hot water fully electrically heated

Advertisement

The electrical single heater consists of a, single coil heat exchanger, control components, thermo probe,
float switch, high pressure hoses, and connections.
THIS MACHINE SHOULD BE PROTECTED FROM FREEZING AT ALL TIMES. (SEE MAINTENANCE)
Place system in any suitable location. Adjust the leg bolts to level the unit. It is recommended to provide
ample room and support for installation, maintenance, and operation of elevated systems. Drainage
should be provided near the unit.
The pumping unit is designed to be located on top of the heat exchanger, although it may be located
beside it.
In every Electrically Heated System the following standard features can be found:
1. Automatic start circuit complete with manual override
2. Automatic time delay stop circuit
3. Automatic temperature controlled heat exchanger
4. Thermal safety shutdown on pumping system to protect pump components
5. Low water shutdown circuit to protect heating elements from lack
of water in the heat exchanger
6. Corrosion resistant incoloy heating elements (tube type)
7. 50' of 3/8" steel braided hose
8. High pressure trigger gun
9. Lance complete with chemical valve
10. Chemical injection system
11. Complete motor fusing and overload protections
Note: Some of these features may not apply to your build. Check with serial and model number