Do not place nor install near flammable or explosive materials. 6.2 Electrical Interface Description of BCU600050 ........... 5 6.3 Electrical Interface Description of LPBA48050-OH ........6 Install the product out of reach of children. 6.4 System Wiring Schematic ................. 6 6.5 Switch On / Off...
2. BCU600050 is the controller of the whole system, so each system must have one BCU600050; · 3. Our system consists of at least 2 LPBA48050-OH + 1 BCU600050 and up to 10 LPBA48050-OH + 1 After unpacking, please check the product for damages and missing parts.
30.5±1 Gross Weight(KG) 34.5±1 5.3 Battery System Specifications SPECIFICATIONS FOR BATTERY SYSTEM BATTERY SYSTEM LPBA-5.1-OH LPBA-7.7-OH LPBA-10.2-OH LPBA-12.8-OH LPBA-15.4-OH Battery Module LPBA48050-OH(2.56kwh,51.2v) Number of Modules 5.12 7.68 10.24 12.8 15.36 Total Energy [Kwh] Usable Energy [kWh] (90%DOD) 11.5 13.8 102.4 153.6...
LiFePO4 Battery System LiFePO4 Battery System 6. ELECTRICAL CONNECTIONS 6.3 Electrical Interface Description of LPBA48050-OH 6.1Battery System Features The batteries have been fitted with multiple protection systems to ensure the safe operation of the system. Some of the protection system includes: •...
LiFePO4 Battery System LiFePO4 Battery System 7.2 Product size information 300≤d≤500 90° 90° Ground(Two rows installtion) Installation Procedure 7.3 Tools 7.4 Floor installation with base Installation Location Requirements Wall ≥300mm ≥300mm Note: 1. If more than 4 batteries are used, base mounting is recommended. 2.
LiFePO4 Battery System LiFePO4 Battery System 7.5 Wall-Mounted Installation Process Note: 1. The number of wall-mount installations should not exceed four. Installation Location Requirements 2. Please make sure that the weight capacity of wall should exceed 150kg. Install Environment 0≤d≤5° 0≤d≤5°...
LiFePO4 Battery System LiFePO4 Battery System SOC LED fault message 7.8 Battery system switch operation Remark Status Fault LED LED1 LED2 LED3 LED4 Soft Start Failed Power On Standby/soft Start Flash Flash Press Soc To Flash Discharging Charging Running Battery Voltage High Battery Voltage Low Cell Voltage High Cell Voltage Low...
LiFePO4 Battery System 9.2Troubleshooting When the red / green LED on the panel is flashing or normally on, it does not mean that the Battery system is abnormal, it may be just an alarm or protection. Please check the ‘LED fault message’ in chapter 7 for the detailed faulty definition before any trouble-shooting steps.