Technical Information; Technical Specification; Equipment - BUILD TEST SOLUTIONS BTS-Pulse 2.0 Instruction Manual And Safety Manuallines

Pulse - air permeability measurement system
Table of Contents

Advertisement

4 Technical Information

4.1 Technical Specification

Maximum Operating Pressure
Operating Voltage
Max Power Consumption
Min Operating Temperature
Max Operating Temperature
Outlet Filtration
Communications
Storage
External Dimensions
Weight
Ancillaries Supplied
System Outputs

4.2 Equipment

The Pulse device comprises the following fundamental components which are supplied by BTS.
4.2.1 Pulse Air Receiver
The Pulse Air Receiver contains:
39.8 litre air receiver tank and connections
Air nozzle silencer for main air release
Analogue pressure gauge
Charge port for compressor connection
Drain valve port (in the base of the unit)
Absolute pressure and temperature sensor
Interface panel
Control PCB
Connections are labelled below:
Pulse 2.0
10 Bar / 145 Psi / 1,000 kPa
220-240V 50Hz (110v available)
569W, 2.63A (compressor)
4°C (frost free)
40°C
5μm (particulate)
2.4 GHz and 5.0 GHz IEEE 802.11ac wireless, Bluetooth 5.0, BLE
8GB (up to 20,000 test files)
Air receiver: Ø 386 x 900 (H) mm
Controller:
305 (L) x 270 (W) x 144 (H) mm
Compressor: 350 (L) x 150 (W) x 370 (H) mm
Air receiver: 14.0kg
Controller:
3.0kg
Compressor: 16.0kg
1x 3m IEC to mains plug cable;
1x 2m IEC compressor power cable;
1x 2m air delivery hose;
1x 4m Controller CAT5e data cable
Air Leakage rate (m³/h)
Air Leakage per hour, Q (m³/h)
Air changes per hour Q (h¯1)
Effective Leakage area (m²)
Air Permeability (m³/m²h)
Achieved Pressure Range (Pa)
Page 7 of 28