Step 3.
Test Easylube before installation:
► The Easylube can be tested by setting all four DIP switches to the ON
position. Use a ball pen or similar tool ( small screwdriver).
► In this test mode the Easylube will cycle 7 to 8 seconds moving the red piston
downward automatically. A small amount of grease should be discharged.
► After the test mode is successfully completed, go to step 4.
 Caution:
Whenever the red indicator light is flashing during test mode, remove the
battery and reset the DIP switches, then put the battery back to restart.
Step 4.
Set/change the dispense period time:
► Remove the battery from the body assembly.
► Set the levers on the switch to correspond to the time perod required.
Table 1. DIP-switch setting for dispense period time
DIP switch
Dispense
"ON"
period
Month
1
1
2
2
3
1+2
4
4
5
1+4
6
2+4
7
1+2+4
8
8
9
1+8
10
2+8
11
1+2+8
12
4+8
The lubricator can be set to any of 12 (represents months) dispensing periods. It will be empty at
the end of the chosen setting. Each monthly setting dispenses the same amount oflubricant per
cycle, but at a different frequency.
Time span
between cycles
Hours
2
4
6
8
10
12
14
16
18
20
22
24
BONDIS bvba – Cleydaellaan 16/1 – 2630 Aartselaar – BELGIUM
Tel .: +32 3 234 29 18 – Fax: +32 3 233 13 10 – Email: info@bondis.com
ISO 9001:2008 n° 22714 – www.bondis.com
Amount/
Amount/
cycle
day
ml
ml
5
2.5
1.67
1.25
1.00
0.83
0.417
0.71
0.63
0.56
0.50
0.45
0.42
Amount/
Amount/
week
month
ml
ml
35
150
17.5
75
11.67
50
8.75
37.5
7.00
30
5.83
25
5.00
21.43
4.38
18.75
3.89
16.67
3.50
15
3.18
13.64
2.92
12.5