FAN WITH ELECTRONICALLY COMMUTATED EXTERNAL-ROTOR MOTOR
& Note :
Be sure to familiarize yourself with these instructions before working on this unit. Not paying attention to these
warnings and instructions may lead to malfunctions and failures or may seriously endanger human life.

Table of Contents :

01
02
TYPICAL FEATURES AND PROPER USE
03
04
05
06
07
08
DIAGNOSTICS
09
10
11
12
13
USER'S GUIDE
Fan Code:
0310-4-0135
Fan type : R10R-56LPS-ES50B-04C10
Symbols :
- important values
- valuable information

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R10R-56LPS-ES50B-04C10 and is the answer not in the manual?

Questions and answers

Summary of Contents for HIDRIA R10R-56LPS-ES50B-04C10

  • Page 1: Table Of Contents

    FAN WITH ELECTRONICALLY COMMUTATED EXTERNAL-ROTOR MOTOR Fan Code: 0310-4-0135 Fan type : R10R-56LPS-ES50B-04C10 & Note : Be sure to familiarize yourself with these instructions before working on this unit. Not paying attention to these warnings and instructions may lead to malfunctions and failures or may seriously endanger human life.
  • Page 2: Safety

    The risk of pulling into rotating part. Do not wear any loose clothing (e.g. tie) or jewellery. Long hair must be protected with a cap. Risk of injury! 2 / 8 © Copyright HIDRIA d.o.o., All rights reserved. Document is subject to change without prior notification.
  • Page 3 External sensor power supply 10VDC (max 30mA). Maintenance free ball-bearings and other components through the expected life-time. The device is compatible with Modbus protocol RTU. Please read additional instructions about Hidria EC Modbus parameters and additional information for general purpose using MODBUS (www.modbus.org) .
  • Page 4: Operating Conditions

    - IEC 60034-1 - Data on the nameplate established at a point of nominal load according to standard for Rotational electrical machines. 4 / 8 © Copyright HIDRIA d.o.o., All rights reserved. Document is subject to change without prior notification.
  • Page 5: Installation And Connection

    3. Push the cable end into terminal. 4. Release the spring - screwdriver. Dimensions: See Appendix - technical drawing : VENTILATOR 0310-4-0135 5 / 8 © Copyright HIDRIA d.o.o., All rights reserved. Document is subject to change without prior notification.
  • Page 6: Speed Control

    - Linear voltage input (0-10V) or PWM input (PWM duty cycle 0-100%). - MODBUS RTU protocol (Additional information are in documentation "Hidria EC Modbus parameters" and on www.modbus.org. Linear voltage input is the most common and it is described below. The current input is also widely used, where long cables are necessary. PWM input is used for electromagnetic noisy environments.
  • Page 7: Putting Into Operation

    In the event of fan failure is detected (short/open circuit of electronics, windings ...), never try to repair the fan, but replace it with a new one or return it to the manufacturer for repair or replacement. 7 / 8 © Copyright HIDRIA d.o.o., All rights reserved. Document is subject to change without prior notification.
  • Page 8: Protective Features

    Please refer to the homepage at www.hidria.com for a list of our subsidiaries worldwide. Hidria reserves the right to change any specifications or data without notice. 8 / 8 © Copyright HIDRIA d.o.o., All rights reserved. Document is subject to change without prior notification.

This manual is also suitable for:

0310-4-0135

Table of Contents