Manuale Operativo
DATI TECNICI
TEMPERATURA DI RIFERIMENTO
TEMPERATURA DI ESERCIZIO
TEMPERATURA DI STOCCAGGIO
ATTACCO DI PROCESSO
GUARNIZIONE CONSIGLIATA
CHIAVE DI SERRAGGIO
COPPIA DI SERRAGGIO
CLASSE PROTEZIONE (EN 60529)
MATERIALE SENSORE
MATERIALE CONTENITORE
OPZIONI
USCITA SERIALE(CLASSE PROTEZIONE IP40)
CONTENITORE DA INCASSO
scale di VUOTO
ALIMENTAZIONE ESTERNA
MO.DFP.538.R3
TECHNICAL DATA
REFERENCE TEMPERATURE
SERVICE TEMPERATURE
STORAGE TEMPERATURE
PROCESS COUPLING
RECOMMENDED GASKET
TIGHTENING WRENCH
TIGHTENING TORQUE
PROTECTION CLASS (EN 60529)
CASE EXECUTION MATERIAL
SENSOR EXECUTION MATERIAL
OPTIONALS
SERIAL OUTPUT(PROTECTION CLASS IP40)
BUILT-IN CASE
VACUUM scales
EXTERNAL FEEDING
page 7
Operating Manual
GB
+23°C
0/+50°C
-10/+60°C
1/2" G MALE
USIT A 63-18
27mm
28Nm
IP65
ALLUMINIO / ALUMINUM
INOX 17-4 PH
RS232C (Tank SUB D 9 pole FEMALE)
ALUMINUM (front panel: IP65)
-1/+1 -1/+2.5 -1/+5 bar
12 I 24 VDC