Fenix Watts 860 User Manual page 57

Electric floor heating thermostat
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 37
ITCS:
08
Intelligent Temperature Control System activates
your device in advance (2 hours as maximum) to
provide for required temperature to be achieved at
pre-programmed time following your weekly program.
The automatic control system works as follows:
When you activate your thermostat for the first time,
the system will measure the time needed by the
device to achieve pre-set temperature. The thermostat
will re-measure the time upon every program change
to compensate for changes and effects of outside
temperature. Now you may program your thermostat
without needing to pre-edit temperature; your
thermostat will do so automatically.
st
1
.H The first heating (for cement, concrete floor,
09
Generally, the function is used right after installation to
prevent your floor from getting damaged by the first
heating.
The first heating function works as follows:
2 hours of operation during 24 hours on the first day,
and 1 extra hour is added every subsequent day,
during 21 days. During this period, floor temperature
(or room temperature unless floor sensor is activated)
is limited to 20°C.
Clr ALL: Default Setup
10
Press and hold (OK) for 10 seconds to reset default
temperatures and user parameters to default setup
values. The function also resets user programs.
* Caution:
Before making use of the function, check whether all
elements needed to reset the device are available.
Software Version
11
Vers __._
End: Exit Parameter Menu
12
To exit the Parameter menu and to return to ordinary
operation, press (OK).
etc.)