Franklin Electric Little Giant 558223 Owner's Manual

Franklin Electric Little Giant 558223 Owner's Manual

4” high-head filtered effluent pump

Advertisement

Quick Links

P. O. Box 12010
Oklahoma City, OK 73157-2010
405.947.2511 • Fax: 405.947.8720
www.LittleGiantPump.com
CustomerService-WTS@fele.com
BEFORE INSTALLING PUMP, BE SURE TO READ THIS OWNER'S
MANUAL CAREFULLY.
Fill the pump with water before starting or the
C A U T I O N
pump will be damaged. The motor on this pump is guaranteed by
the manufacturer, and in the event of failure it must be returned
to an authorized service station for repairs. The motor warranty is
void if repairs are not made by an authorized repair station.
INSPECT THE SHIPMENT
Examine the pump when it is received to be sure there has been no
damage in shipping. Should any be evident, report it immediately
to the dealer from whom the pump was purchased. Please check
the pump package to see that it includes pump, motor, and motor
leads (if your pump purchase includes a motor).
Make certain that your available voltage corresponds to that of
your motor.
4" HIGH-HEAD FILTERED
EFFLUENT PUMP
OWNER'S MANUAL
READ AND FOLLOW SAFETY INSTRUCTIONS
This is the safety alert symbol. When you see this symbol
on your pump or in this manual, look for one of the
following signal words and be alert to the potential for personal
injury:
D A N G E R
personal injury, death, or major property damage if ignored.
W A R N I N G
personal injury, death, or major property damage if ignored.
C A U T I O N
personal injury or major property damage if ignored.
The label NOTICE indicates special instructions, which are
important but not related to hazards.
Carefully read and follow all safety instructions in this manual
and on pump.
Keep safety labels in good condition.
Replace missing or damaged safety labels.
WA R N I N G
Hazardous voltage.
Can shock, burn, or
cause death.
Ground pump before
connecting to power
supply. Disconnect
power before working
on pump, motor
or tank.
warns about hazards that will cause serious
warns about hazards that can cause serious
warns about hazards that will or can cause minor
Wire motor for correct voltage.
See Electrical Information section
of this manual and motor nameplate.
Ground motor before connecting to
power supply.
Meet National Electrical Code,
Canadian Electrical Code, and
local codes for all wiring.
Follow wiring instructions in this
manual when connecting motor
to power lines.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Little Giant 558223 and is the answer not in the manual?

Questions and answers

Summary of Contents for Franklin Electric Little Giant 558223

  • Page 1 4” HIGH-HEAD FILTERED EFFLUENT PUMP P. O. Box 12010 Oklahoma City, OK 73157-2010 OWNER’S MANUAL 405.947.2511 • Fax: 405.947.8720 www.LittleGiantPump.com CustomerService-WTS@fele.com READ AND FOLLOW SAFETY INSTRUCTIONS This is the safety alert symbol. When you see this symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for personal injury: D A N G E R...
  • Page 2: Installation Records

    THIS EQUIPMENT IS INTENDED FOR INSTALLATION BY Purchased from: TECHNICALLY-QUALIFIED PERSONNEL. FAILURE TO INSTALL IT IN COMPLIANCE WITH NATIONAL AND LOCAL Date of installation: ELECTRICAL CODES AND WITH FRANKLIN ELECTRIC Pump model*: RECOMMENDATIONS MAY RESULT IN ELECTRICAL SHOCK Pump date code*: OR FIRE HAZARD, UNSATISFACTORY PERFORMANCE, Well inside diameter (in/mm): AND EQUIPMENT FAILURE.
  • Page 3: Test Running

    TEST RUNNING REMOVABLE POPPET CHECK VALVE If test running pump before installation: 4” submersible pumps with a 1-1/4” discharge are supplied with a spring-loaded, removable poppet check valve assembly 1. Ensure that the power supply corresponds with that shown (Figure 1). This check valve can be removed from the pump on the nameplate of the motor.
  • Page 4 provide protection against only induced voltage surges on In addition, protect the entire underwater installation from water secondary power lines; they are not effective against direct currents, ice, boats, anchors, debris, vandalism, and other hits. hazards. 6. Mount the control box in an area protected from rain, snow, direct sunlight, or other high temperatures as this may cause Never run the pump unless it is completely C A U T I O N...
  • Page 5: Troubleshooting

    TROUBLESHOOTING 1. PUMP FAILS TO START a) Electrical trouble - call dealer or electrician b) Drawdown protection device has pump turned off c) Overload tripped d) Reset low pressure cutoff switch (if installed) 2. PUMP FAILS TO DELIVER WATER a) Air lock in pump b) Clogged intake screen c) Insuffi...
  • Page 6 THIS PAGE INTENTIONALLY LEFT BLANK...
  • Page 7 Franklin Electric Company, Inc. Franklin Electric Company, Inc. warrants its new products to be free of defects in material and workmanship for a period of 1 year from date of installation or 2 years from date of manufacture, whichever comes fi rst. Warranty does not cover applications pumping saltwater or other corrosive liquids.
  • Page 8 Little Giant is a registered trademark of Franklin Electric Co., Inc. ® ©2007 Franklin Electric Co., Inc. Form 998450 — 05/2007...

Table of Contents