型号
Model
壳架等级额定电流 Inm(A)
Frame rated current Inm(A)
整定电流 Ir(A)
Setting current Ir(A)
额定绝缘电压 Ui(V)
Rated insulation voltage Ui(V)
额定冲击耐受电压 Uimp(kV)
Rated impulse withstand voltage Uimp(kV)
额定工作电压 Ue(V)
Rated working voltage Ue(V)
工频耐受电压 U(1 分钟)(V)
Power frequency withstand voltage U(1min)(V)
使用类别
Usage category
额定短时耐受电流 Icw(kA /1s)
Short-time withstand current Icw(kA /Isd)
极数
Number of poles
分断能力级别
Breaking capacity
额定极限短路分断能力 Icu(kA)
Rated ultimate breaking capacity Icu(kA)
额定运行短路分断能力 Ics(kA)
Rated service breaking capacity Ics(kA)
操作性能寿命(次)
Operational performance
life (times)
飞弧距离 (mm)
Flashover dIsdtance (mm)
注:Notes:
Ir 整定值在 T 型、GT 型、电动机保护型时,大小为原整定值范围内的任意整数值。In case of T type and
GT type, motor protection type panel the Ir setting value Isd any integral value within limiTsd of original
setting values.
3.2 NDM2E 控制器电流、时间调整 Current and time adjustment of NDM2E controller
注意:控制器电流、时间的调整必须由专业技术人员负责。
Notes: Adjustment of current and time of the controller should be carried out by specialized technical
personnel.
3.2.1 NDM2E 控制器控制面板图及参数组成
ComponenTsd of the control panel figure and parameter of NDM2E controller
断路器控制面板由十五部分组成:
Control panel of the breaker Isd consIsdted of 15 below:
地址:上海市浦东新区申江南路 2000 号
文件编号:NDT2920018
表 2(续) NDM2E 主要技术参数
Table 2 (Continued) Main technical parameters of NDM2E
电气寿命
Electrical life
机械寿命
Mechanical life
邮编:201315
第 9 页 共 39 页
NDM2E-400
NDM2E-630
400
630
280、315、
200、225、
350、400、
250、280、
450、500、
315、350、
550、600、
400
630
800
800
8
8
400
400
3500
3500
B
B
5
8
3
3
M
H
M
65
100
65
65
65
65
7500
7500
10000
10000
≤100
≤100
电话:(021)68586699
文件版本:5
NDM2E-800
800
400、450、
500、550、
600、630、
700、750、
800
800
8
400
3500
B
10
3
H
M
H
100
65
100
65
65
65
7500
10000
≤100
传真:(021)23025796
Need help?
Do you have a question about the NDM2E Series and is the answer not in the manual?
Questions and answers