M-system 6BPA Instruction Manual

Frequency transmitter

Advertisement

INSTRUCTION MANUAL
FREQUENCY TRANSMITTER
(field-selectable freq. range)
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System's Sales Office or representatives.
■ PACKAGE INCLUDES:
Transmitter module ............................................................(1)
Outdoor enclosure ...............................................................(1)
Mounting screws
Bolt (M8 × 15) ....................................................................(4)
Spring washer for M8 .......................................................(4)
Mounting bracket assembly (optional)
Mounting bracket ..............................................................(1)
M10 U-bolt .........................................................................(2)
Nut for M10 .......................................................................(4)
Spring washer for M10 .....................................................(4)
■ MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
MODEL
POINTS OF CAUTION
■ GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■ ENVIRONMENT
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -5 to +70°C
(23 to 158°F) in order to ensure adequate life span and
operation.
■ WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■ AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
6BPA
EM-8888 Rev.1 P. 1 / 5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 6BPA and is the answer not in the manual?

Questions and answers

Summary of Contents for M-system 6BPA

  • Page 1 (field-selectable freq. range) BEFORE USE ..POINTS OF CAUTION Thank you for choosing M-System. Before use, please check ■ GENERAL PRECAUTIONS contents of the package you received as outlined below. • Before you remove the unit or mount it, turn off the power If you have any problems or questions with the product, supply and input signal for safety.
  • Page 2: Component Identification

    • Case Details Cable Entry Conduit Internal Earthing Screw Specifications Case Gasket External Earthing Screw Transmitter Module Cover Spring Clip(s) Knurled Knob(s) EM-8888 Rev.1 P. 2 / 5 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 3 92 (3.62) 110 (4.33) 4–M8, 12 deep SPACE REQUIRED TO REMOVE COVER 114 (4.49) 110 (4.33) 2–G 1/2, 1/2NPT, M20x1.5 or PG13.5 EM-8888 Rev.1 P. 3 / 5 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 4: Installation

    3) Output: Check that the load is within the permissible limit including wiring resistance. Supply Voltage (V) – 13 (V) Load Resistance (Ω) = 0.02 (A) (including leadwire resistance) EM-8888 Rev.1 P. 4 / 5 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 5: Adjustment Procedure

    114 – 130 285 – 325 570 – 650 1140 – 1300 M-System offers a series of lightning surge protectors for protection against induced lightning surges. Please contact M-System to choose appropriate models. EM-8888 Rev.1 P. 5 / 5 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN...

Table of Contents