Congratulations and thank you for purchasing Skar Audio amplifiers, the logical choice in mobile audio amplification. Your amplifiers have been designed and engineered with the highest quality components and top of the line workmanship to help you reach the superior sound you are after.
To achieve optimal performance of your system, please take a few moments to read over this Owner's manual or visit authorized dealer if needed before starting your installation.
Rated power output | RP-350.1D | RP-800.1D | RP-1200.1D | RP-1500.1D | RP-2000.1D |
|
150Watts x 1 250Watts x 1 350Watts x 1 | 370Watts x 1 600Watts x 1 800Watts x 1 | 500Watts x 1 800Watts x 1 1200Watts x 1 | 550Watts x 1 930Watts x 1 1500Watts x 1 | 800Watts x 1 1400Watts x 1 2000Watts x 1 |
Working impedance | 1 ohm stable | 1 ohm stable | 1 ohm stable | 1 ohm stable | 1 ohm stable |
Input Sensitivity | 6V ~ 0.2V | 6V ~ 0.2V | 6V ~ 0.2V | 6V ~ 0.2V | 6V ~ 0.2V |
Low Pass Filter | 50Hz ~ 220Hz | 50Hz ~ 220Hz | 50Hz ~ 220Hz | 50Hz ~ 220Hz | 50Hz ~ 220Hz |
Subsonic Filter | Off ~ 50Hz | Off ~ 50Hz | Off ~ 50Hz | Off ~ 50Hz | Off ~ 50Hz |
Bass Boost | 6dB / 12dB | 6dB / 12dB | 6dB / 12dB | 6dB / 12dB | 6dB / 12dB |
Frequency Response | 20 ~ 250Hz | 20 ~ 250Hz | 20 ~ 250Hz | 20 ~ 250Hz | 20 ~ 250Hz |
Signal to Noise Ratio | 85 < | 85 < | 85 < | 85 < | 85 < |
Efficiency @ 4ohm | Over 90% | Over 90% | Over 90% | Over 90% | Over 90% |
THD @ 4ohm | < 0.1% | < 0.1% | < 0.1% | < 0.1% | < 0.1% |
Damping Factor | 150 < | 150 < | 150 < | 150 < | 150 < |
Fuse Rating | 30A | 80A | 100A | 120A | 200A |
Dimensions ( L inches ) 6.30 W x 2.20 H inches |
6.23 inches | 10.13 inches | 11.81 inches | 13.267 inches | 17.71 inches |
All features are subject to change in the continuing effort to improve the products without notice.
Rated power output | RP-3500.1D | RP-4500.1D |
|
1200Watts x 1 2300Watts x 1 3500Watts x 1 7000Watts x 1 |
1600Watts x 1 2900Watts x 1 4500Watts x 1 9000Watts x 1 |
Working impedance | 1 ohm stable | 1 ohm stable |
Input Sensitivity | 6V ~ 0.2V | 6V ~ 0.2V |
Low Pass Filter | 35Hz ~ 250Hz | 35Hz ~ 250Hz |
Subsonic Filter | 10Hz ~ 50Hz | 10Hz ~ 50Hz |
Bass EQ | 0dB ~ 9dB | 0dB ~ 9dB |
Phase Control | 0 ~ 180 Degree | 0 ~ 180 Degree |
Remote Control | Included | Included |
Strapped Connection | Included | Included |
Frequency Response | 20 ~ 250Hz | 20 ~ 250Hz |
Signal to Noise Ratio | 85 < | 85 < |
Efficiency @ 4ohm | Over 90% | Over 90% |
THD @ 4ohm | < 0.1% | < 0.1% |
Damping Factor | 200 < | 200 < |
Fuse Rating | 350A | 450A |
Strapped Fuse Rating | 700A | 900A |
Dimensions ( L inches ) 8.27 W x 2.44 H inches |
18.90 inches | 22.05 inches |
All features are subject to change in the continuing effort to improve the products without notice.
4 CHANNEL AMPLIFIER
5 CHANNEL AMPLIFIER
Rated power output | RP-75.4AB | RP-150.4AB | RP-600.5 |
|
75Watts x 4 115Watts x 4 na 250Watts x 2 |
150Watts x 4 250Watts x 4 na 500Watts x 2 |
60Watts x 4 + 170Watts x 1 90Watts x 4 + 270Watts x 1 370Watts x 1 180Watts x 2 |
Working impedance | 2 ohm stable | 2 ohm stable | 2 ohm for CH1/4, 1 ohm for CH5 |
Input Sensitivity | 6V ~ 0.2V | 6V ~ 0.2V | 6V ~ 0.2V |
High Pass Filter | 20Hz ~ 5KHz | 20Hz ~ 5KHz | 20Hz ~ 5KHz - CH1/2 & CH3/4 |
Low Pass Filter | 50Hz ~ 500Hz | 50Hz ~ 500Hz | 50Hz ~ 250Hz for CH5 |
Subsonic Filter | na | na | 10Hz ~ 50Hz for CH5 |
Bass Boost Frequency Response | 6dB / 12dB 20Hz ~ 20KHz | 6dB / 12dB 20Hz ~ 20KHz | 0 ~ 12dB for CH5 20Hz ~ 20KHz for CH1/4, 20 ~ 250Hz for CH5 |
Signal to Noise Ratio | 105 < | 105 < | 105 < for CH1/4, 85 < for CH5 |
Efficiency @ 4ohm | Over 65% | Over 65% | Over 65% for CH1/4, Over 90% for CH5 |
THD @ 4ohm | < 0.1% | < 0.1% | < 0.1% |
Damping Factor | 150 < | 150 < | 150 < |
Fuse Rating | 60A | 120A | 80A |
Dimensions ( L inches ) 6.30 W x 2.20 H inches |
13.78 inches | 17.72 inches | 16.93 inches |
All features are subject to change in the continuing effort to improve the products without notice.
RP-350.1D, RP-800.1D, RP-1200.1D, RP-1500.1D, RP-2000.1D, RP-3500.1D, RP-4500.1D, RP-75.4AB, RP-150.4AB & RP-600.5 working voltage is 8.5V to 16Volts
Fuse rate
RP-350.1D: 30A
RP-800.1D: 80A
RP-1200.1D: 100A
RP-1500.1D: 120A
RP-2000.1D: 200A
RP-3500.1D: 350A
RP-4500.1D: 450A
RP-75.4AB: 60A
RP-150.4AB: 120a
RP-600.5: 80A
BATT + (+12V POWER )
Before mounting amplifiers, disconnect the negative cable from the battery to protect any accidential damage to your amplifiers and audio system.
RP-2000.1D, RP-3500.1D & RP-4500.1D are designed to use o ga power and ground connection Rest of RP amplifiers are designed to use 4 gauge power and ground connection.
Connect the power cables to power terminal +12V.
All RP-series amplifiers are not equipped with fuses so that external fuses should be used. Connect one end of fuse holder to the power cable going into the amplifiers and the other end of fuse holder to positive battery. This fuse location will protect the system and the vehicle against the possibility of a short circuit in the power cable. Be sure to use fuses and fuse holder adequate for the application.
Locate a secure grounding connection as close to amplifier as possible. Make sure the location is clean and provides a direct electrical connection to the frame of the vehicle. The ground needs to have as low of a resistance as possible. Connect one end of a short piece of the same size cable as the power cable to the grounding point or to one of your batteries or battery bank. Run the other end of 4 ga cable to the mounting location of the amplifiers for connection to the amplifiers ground terminals and connect the ground cable to the GND ( ground terminal ).
Run a remote turn on cable from the switched +12V source. This may be a toggle switch, a relay, your source unit's remote trigger cables, or power antenna trigger cable.
Connect the remote turn on cable to the REM ( remote ) terminal.
RP-series Digital Monoblock's minimum workin impedance is lohm
Strappable connection makes two of same amplifiers strapped to 2 ohm.
Strappable connection makes the power double than their 1 ohm power.
Please read the following connection and diagram carefully to make correct connection.
INPUT CONNECTION;
POWER & SPEAKER CONNECTION;
Fully adjusted signal is transferred from master to slave amp via Rca cable. Master amplifier controls all crossover and remote control over Slave amplifier
In strappble connection,
Minimum working impedance is 2 ohm.
Impedance lower than 2 ohm can damage the amplifier
All RP-monoblock minimum working voltage is 8.5V to 16Volts.
RP-75.AB & RP150.4AB minimum working impedance is 2 ohm stereo or 4 ohm mono.
RP-600.5 minimum working impedance is 2 ohm stereo or 4 ohm mono for CH1 ~ Ch4 and 1 ohm for CH5
RP-series amplifiers have protection features to prevent any damages from misuse or faulty conditions.
If RP-series amplifiers sense excessive heat, short circuited speakers DC, or voltage the protection indicator will light, and the system will be turned off.
In order to check the problem, you should turn all levels down and all power off and carefully check the installation for wiring mistakes or short.
If RP-series amplifiers shuts down due to excessive heat, They will be working later when it is cooled down
Before removing your amplifier, refer to the list below and follow the suggested procedures.
@ Please check speaker cables and reverse polarity.
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Advertisement
Need help?
Do you have a question about the RP-800.1D RP-1200.1D RP-2000.1D and is the answer not in the manual?
Questions and answers