Page 9
User manual TDT + 4. - ELEMENT DESCRIPTION 4.1.- TDT + 1.- Satellite IF input 2.- Satellite IF output 3.- RF input 4.- RF output 5.- Programmer / PC connector 6.- Powering input 7.- LED 8.- Control BUS connector / +24V TDT+ Product reference Indicate the programmer...
Page 10
User manual TDT + 4.2.- Power supply unit + 18V + 15V + 5V + 24V Connectors to power the modules (1)) LED on Mains input 220V~ 15%~ (ref. 5025) The power supply unit can power a 230V~ 15%~ (ref. 5029) TDT+ modules.
Page 12
User manual TDT + 4. 4. - Programmer PCT 4.0 The programmer consists of 4 buttons: : (short press) - Selection of parameter (positioning of the cursor). : Modification of the parameter chosen P C T 4 .0 by the cursor (flashing) U N IV E R S A L : (short press) - Change menu...
Page 13
User manual TDT + 5. - PROGRAMMING PROCEDURE WITH PCT 4.0 5.1.- MAIN MENU Note: The symbol rate will not be shown if a.- Input menu Insert programmer front the “Auto Config” option on the programming connector TDT+ extended menu is activated (see module ("PRGM").
Page 14
User manual TDT + selected in section 5.2.a, as it will be The next parameter, spectrum inversion (IQ), The first two digits correspond to the mantis selected automatically according to the makes it possible to change the IQ and the last corresponds to the exponent. automatic connection table.
Page 15
User manual TDT + 5.2.- EXTENDED MENU Holding down the key for more than 3 When the working mode "Auto config" is Holding down the key gives access to the selected, the menus Input and QAM will be seconds will bring up a series of menus for different configurations of the unit, which are modified.
User manual TDT + b.- Language menu 5.3.- SAVING PARAMETERS 5.4.- STATUS LEDS The last extended menu allows the language Once the required value has been selected The LEDS indicate the following status: to be changed: in any of the menus (normal or extended), to save the data press the key for approximately 3 seconds.
Page 17
User manual TDT + 6.- ACCES CODE The user must enter the correct password The TDT+ allows a 4-digit access code to be Validating used optionally, using values outside of the and save it (by pressing the key for password input frequency range (0000-0949 and approximately 3 seconds).
User manual TDT + 7.- CONTROLLING THE DEVICE This version TDT+ permits configuration and control from a PC, both locally and via remote control. b.- Remote control a.- Local control well program previously user must have "Headend mentioned, it is necessary to have a Management"...
Page 19
User manual TDT + 8.- TYPICAL APPLICATION 8.1.- APPLICATION EXAMPLE (SKY LIFE) 5025 5025 7 x 5023 7 x 5023 75 ohm 4061 4510 5025 7 x 5023 QAM output...
Page 20
User manual TDT + 9.- NORMS FOR RACK MOUNTING (max. 35 TDT+ - 7 subracks 5 units high - 8,7”) gap (approx. 3-5 cm) at the top of the Rack. 9.1.- Installation rack with To mount the units in the rack with The new air will enter through the bottom of ventilation facilities.
Need help?
Do you have a question about the TDT+ and is the answer not in the manual?
Questions and answers