Download Print this page
NewMar Centurion CR48-10 Installation & Operation Manual
NewMar Centurion CR48-10 Installation & Operation Manual

NewMar Centurion CR48-10 Installation & Operation Manual

Rectifier system

Advertisement

Quick Links

Overview
Shelf Installation
Rectifier Installation/Operation
Shelf Controller And Rectifier Operation/Adjustment
Alarm Contacts
Battery Charging
Removing and Installing the Controller Assembly
System Component Options
Specifications
Dimensional Drawings
P.O. Box 1306, Newport Beach, California 92663 • Phone: 714-751-0488 • Fax: 714-957-1621 • E-Mail: techservice@newmarpower.com
Centurion Rectifier System
CR48-10: 48 Volt, 10 Amp Rectifier
CR24-20: 24 Volt, 20 Amp Rectifier
CRS: Rectifier Shelf (3 rectifier bay controller)
INSTALLATION / OPERATION MANUAL
A) Mounting
B) AC Input
C) DC Output/Battery Connection Points
A) Installation
B) Rectifier Module Output Indications
A) Start-Up
B) Output Voltage Adjustment
C) Controller Indications
A) Minor
B) Major/Output OK
C) Alarm Connector Wire Assembly
A) Power Function Manager, Model PFM-400
B) Circuit Breaker Distribution Panels
www.newmartelecom.com
Models:
Section
I
II
III
IV
V
VI
VII
VIII
IX
X
M-CR-CRS
As of Nov. 2006
1

Advertisement

loading

Summary of Contents for NewMar Centurion CR48-10

  • Page 1 Centurion Rectifier System Models: CR48-10: 48 Volt, 10 Amp Rectifier CR24-20: 24 Volt, 20 Amp Rectifier CRS: Rectifier Shelf (3 rectifier bay controller) INSTALLATION / OPERATION MANUAL Section Overview Shelf Installation A) Mounting B) AC Input C) DC Output/Battery Connection Points Rectifier Installation/Operation A) Installation B) Rectifier Module Output Indications...
  • Page 2 Ear attachments are in the 6” forward mounting position and at the four corners for four point cabinet mounting (contact Newmar for additional mounting ears.) Use the six #6-32 x 1/4" pan head mounting screws and lock washers to secure the ears.
  • Page 3 Note: Contact Newmar if unable to perform the above procedure. in an absorption charge of 28.0 or 56.0 volts for up to 8 hours. Contact Newmar for information.
  • Page 4 IX) Specifications X) Dimensional Drawings Centurion Rectifiers Input Voltage/Frequency: 90-264 VAC* / 47-63 Hz. Input Amperage: 6 amps @ 115V and full load, 3 amps @ 230V and full load Power Factor: .96-.99 Output Voltage/Amperage*: CR48-10: -54.4 VDC, 10 amps continuous CR24-20: +27.2 VDC, 20 amps continuous * 100 % output power available from 105 VAC to 264 VAC;...

This manual is also suitable for:

Centurion cr24-20